• Acta Photonica Sinica
  • Vol. 49, Issue 3, 0306003 (2020)
Ming LEI, Yuan FANG, Huai-yong YU, Yi YANG, Qiang XIANG, and Li-zhe ZHANG
Author Affiliations
  • National Key Laboratory of Inertial Technolog, Beijing Institute of Automatic Control Equipment, Beijing 100074, China
  • show less
    DOI: 10.3788/gzxb20204903.0306003 Cite this Article
    Ming LEI, Yuan FANG, Huai-yong YU, Yi YANG, Qiang XIANG, Li-zhe ZHANG. Scale Factor Test of Resonance Fiber Optic Gyroscope Based on Biased Sawtooth Wave[J]. Acta Photonica Sinica, 2020, 49(3): 0306003 Copy Citation Text show less

    Abstract

    In order to solve the problem that the accuracy of scale factor measurement of Resonance Fiber Optic Gyroscope (RFOG) is limited by the performance of turntable, a new method based on sawtooth equivalent input was proposed. By adding sawtooth wave to the RFOG's phase modulator, which works as equivalent input angular velocity, the RFOG closed-loop transfer functions under turntable input and equivalent input were analyzed, relationship between the parameter of sawtooth and equivalent input angular velocity was given, the scale factor and non-linearity were obtained by the scale factor test system. The scale factor is basically identical to the test result on the turntable, and the non-linearity is also improved from 0.42% to 0.26%. The test results demostrate that the scale factor test system based on sawtooth equivalent input can accurately measure the scale factor of RFOG, and effectively eliminate the measurement errors due to the vibration and imperfect precision of the turntable.
    Ming LEI, Yuan FANG, Huai-yong YU, Yi YANG, Qiang XIANG, Li-zhe ZHANG. Scale Factor Test of Resonance Fiber Optic Gyroscope Based on Biased Sawtooth Wave[J]. Acta Photonica Sinica, 2020, 49(3): 0306003
    Download Citation