    Jun HUANG, Yinbo HUANG, Xingji LU, Zhensong CAO, Gang QI, Zihao YUAN. Measurement and Concentration Inversion of Ozone in Golmud by Laser Heterodyne Spectrometer[J]. Acta Photonica Sinica, 2021, 50(4): 57 Copy Citation Text show less
    Structure diagram of laser heterodyne spectrometer
    Fig. 1. Structure diagram of laser heterodyne spectrometer
    Laser heterodyne spectrum measurement and data processing flow
    Fig. 2. Laser heterodyne spectrum measurement and data processing flow
    Jacobian value of ozone in 3.3 μm
    Fig. 3. Jacobian value of ozone in 3.3 μm
    Gas concentration inversion process of optimal estimation algorithm
    Fig. 4. Gas concentration inversion process of optimal estimation algorithm
    Schematic diagram of line shape function measurement of laser heterodyne spectrometer
    Fig. 5. Schematic diagram of line shape function measurement of laser heterodyne spectrometer
    Measured results of instrument line shape function
    Fig. 6. Measured results of instrument line shape function
    3.3 μm ozone absorption feature measurement and inversion fitting results
    Fig. 7. 3.3 μm ozone absorption feature measurement and inversion fitting results
    Prior profiles and inversion results of ozone concentration
    Fig. 8. Prior profiles and inversion results of ozone concentration
    Ozone column concentration in Golmud
    Fig. 9. Ozone column concentration in Golmud
    ParameterValue

    Linewidth of local oscillator laser/MHz

    Laser power/mW

    Measurement range/cm-1

    Filter bandwidth/MHz

    Sensitivity/μV

    Integration time/ms

    <10

    ~6

    3 039.982~3 040.675

    10~32

    500

    10

    Table 1. Main parameters setting of the system