• Optics and Precision Engineering
  • Vol. 31, Issue 22, 3256 (2023)
Jiayu WANG1, Haodong SHI1,*, Yingchao LI1, Qiang FU1..., Chao WANG1, Zhenwei LIU2 and Huilin JIANG1,*|Show fewer author(s)
Author Affiliations
  • 1College of Optoelectronic Engineering, Changchun University of Science and Technology, Changchun30022, China
  • 2Northeast Industries Group Co., Ltd., Changchun130103, China
  • show less
    DOI: 10.37188/OPE.20233122.3256 Cite this Article
    Jiayu WANG, Haodong SHI, Yingchao LI, Qiang FU, Chao WANG, Zhenwei LIU, Huilin JIANG. Research on polarization optimization of dual-coded spectropolarimeter[J]. Optics and Precision Engineering, 2023, 31(22): 3256 Copy Citation Text show less
    Interface distribution diagram of coated lens
    Fig. 1. Interface distribution diagram of coated lens
    Working principle of PGP
    Fig. 2. Working principle of PGP
    Dual-evaluation based polarization-maintaining optimization method and system structure
    Fig. 3. Dual-evaluation based polarization-maintaining optimization method and system structure
    Change of DOLP at 400 nm
    Fig. 4. Change of DOLP at 400 nm
    Change of DOLP at 500 nm
    Fig. 5. Change of DOLP at 500 nm
    Change of DOLP at 600 nm
    Fig. 6. Change of DOLP at 600 nm
    Experimental scenario: Dual-coded spectropolarimeter(a) and Ground truth(b)
    Fig. 7. Experimental scenario: Dual-coded spectropolarimeter(a) and Ground truth(b)
    Reconstructed spectral polarization image
    Fig. 8. Reconstructed spectral polarization image
    波长/nm优化前优化后标准值相对误差变化
    6000.6860.5990.6178.26%
    5000.6980.5980.6296.04%
    4000.6690.5860.6028.47%
    Table 1. DOLP change of black ferrous rod
    波长/nm优化前优化后标准值相对误差变化
    6000.6160.4300.45439.20%
    5000.6350.4260.45937.70%
    4000.6240.4210.45139.90%
    Table 2. DOLP change of white round plastic
    波长/nm优化前优化后标准值相对误差变化
    6000.7190.4220.41871.00%
    5000.7110.4380.42963.60%
    4000.6920.4260.41267.00%
    Table 3. DOLP change of black round plastic
    波长/nm优化前优化后标准值相对误差变化
    6000.5250.6200.64514.70%
    5000.4940.6020.61917.40%
    4000.3400.5800.61818.70%
    Table 4. DOLP change of red square metal
    Jiayu WANG, Haodong SHI, Yingchao LI, Qiang FU, Chao WANG, Zhenwei LIU, Huilin JIANG. Research on polarization optimization of dual-coded spectropolarimeter[J]. Optics and Precision Engineering, 2023, 31(22): 3256
    Download Citation