• Chinese Optics Letters
  • Vol. 13, Issue 5, 051201 (2015)
Weiwei Pang1, Xiaobing Zheng1, Jianjun Li1、*, Xueshun Shi2, Haoyu Wu1, Maopeng Xia1, Dongyang Gao1, Jianmin Shi1, Tao Qi1, and Qing Kang1
Author Affiliations
  • 1Key Laboratory of Optical Calibration and Characterization, Chinese Academy of Sciences, Hefei 230031, China
  • 2The 41st Institute of China Electronics Technology Group Corporation, Qindao 266555, China
  • show less
    DOI: 10.3788/COL201513.051201 Cite this Article Set citation alerts
    Weiwei Pang, Xiaobing Zheng, Jianjun Li, Xueshun Shi, Haoyu Wu, Maopeng Xia, Dongyang Gao, Jianmin Shi, Tao Qi, Qing Kang. Novel calibration optical path of cryogenic radiometer[J]. Chinese Optics Letters, 2015, 13(5): 051201 Copy Citation Text show less

    Abstract

    We introduce a novel calibration optical path of the cryogenic radiometer, which can avoid the repeated dismounting measurement and eliminate the negative influence of Brewster window effect on calibration result. The novel calibration optical path is used to calibrate the absolute spectral responsivity of the standard transfer detector at 633 nm, the results of which are compared with the ones of the previous structure. It is shown that comparing the previous results to the structure optimization, the measurement uncertainty of laser power reduces by a factor of 2, the measurement uncertainty on the absolute spectral responsivity of the transfer detector decreases by 15%, and the consistence of the calibration on absolute spectral responsivity is 4.0×10 3. The experiment result proves that the novel calibration optical path of cryogenic radiometer can effectively reduce the calibration uncertainty against standard detector and improve the accuracy of calibration.
    PL=1T(NPhA+PS),(1)

    View in Article

    R=U·p·NL·C·VPL,(2)

    View in Article

    PL=NPhA.(3)

    View in Article

    K=RmaxRmin(Rmax+Rmin)/2,(4)

    View in Article

    uPL2=(PhA)2uN2+(NPhA2)2uA2+(NA)2uPh2.(5)

    View in Article

    urPL=uPL/PL=1N2uN2+1A2uA2+1Ph2uPh2=urN2+urA2+urPh2.(6)

    View in Article

    u2(R)=(RU)2u2(U)+(RP)2u2(P)+(RN)2u2(N)+(RC)2u2(C)+(RV)2u2(V)+(RPL)2u2(PL),u2(R)R2=u2(U)U2+u2(P)P2+u2(N)N2+u2(C)C2+u2(V)V2+u2(PL)PL,ur(R)=ur2(U)+ur2(P)+ur2(N)+ur2(C)+ur2(V)+ur2(PL).(7)

    View in Article

    Weiwei Pang, Xiaobing Zheng, Jianjun Li, Xueshun Shi, Haoyu Wu, Maopeng Xia, Dongyang Gao, Jianmin Shi, Tao Qi, Qing Kang. Novel calibration optical path of cryogenic radiometer[J]. Chinese Optics Letters, 2015, 13(5): 051201
    Download Citation