• High Power Laser and Particle Beams
  • Vol. 31, Issue 12, 125103 (2019)
Min Li1, Yonggan Nie1, Shengpeng Li2, Weilong Li1、3, Jinmei Dong1, Yucong Chen1, Tiecheng Zhao1, Ruishi Mao1、*, Zhiguo Xu1, Xincai Kang1, Yongchun Feng1、3, Zulong Zhao1、3, Yanmou Wang1, Weinian Ma1, and Yan Yin1
Author Affiliations
  • 1Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China
  • 2Lanzhou Kejin Taiji Corporation, Ltd, Lanzhou 730000, China
  • 3University of Chinese Academy of Sciences, Beijing 100049, China
  • show less
    DOI: 10.11884/HPLPB201931.190144 Cite this Article
    Min Li, Yonggan Nie, Shengpeng Li, Weilong Li, Jinmei Dong, Yucong Chen, Tiecheng Zhao, Ruishi Mao, Zhiguo Xu, Xincai Kang, Yongchun Feng, Zulong Zhao, Yanmou Wang, Weinian Ma, Yan Yin. Upgrade of CSRe beam diagnostic control system based on EPICS[J]. High Power Laser and Particle Beams, 2019, 31(12): 125103 Copy Citation Text show less

    Abstract

    The experimental Cooling Storage Ring (CSRe) of the Heavy Ion Research Facility in Lanzhou (HIRFL) provides high-quality beam for high-precision mass measurement, atomic physics and other experimental studies. Consequently, accurate measurement of beam parameters is the prerequisite for physical experiments. At present, the control system of CSRe has been upgraded to the EPICS architecture. This paper introduces the current status of the beam diagnostics control system based on EPICS which is affiliated with the accelerator control system. Moreover, some of the beam parameters are measured and analyzed by the upgraded beam diagnostics control system. According to the test results with beam at CSRe, the beam position control system can measure the turn-by-turn position of the injected beam. Furthermore, the calculated turn-by-turn position results show that there is a certain degree of oscillation during the injection process, which affects the injection efficiency directly. The beam current measurement system can achieve precise measurement with DCCT by upgrading a high-resolution data acquisition card, in addition, the D event trigger has been integrated into the beam current control system for receiving the trigger and synchronized information from the virtual accelerator. The upgraded control system is running stably and can measure the beam parameters since the upgrade in 2018 and has been integrated into the graphical user interface (GUI) of the accelerator control system.
    Min Li, Yonggan Nie, Shengpeng Li, Weilong Li, Jinmei Dong, Yucong Chen, Tiecheng Zhao, Ruishi Mao, Zhiguo Xu, Xincai Kang, Yongchun Feng, Zulong Zhao, Yanmou Wang, Weinian Ma, Yan Yin. Upgrade of CSRe beam diagnostic control system based on EPICS[J]. High Power Laser and Particle Beams, 2019, 31(12): 125103
    Download Citation