• Journal of Applied Optics
  • Vol. 43, Issue 3, 409 (2022)
Zhilei LI1, Haifeng LIU1, Weiwei CHI1, Limei ZHOU2,*..., Fang XIE2 and Yangyang LIU2|Show fewer author(s)
Author Affiliations
  • 1State Grid Xiong'an New District Power Supply Company, Baoding 071699, China
  • 2China Electric Power Research Institute Co.,Ltd., Beijing 100192, China
  • show less
    DOI: 10.5768/JAO202243.0301005 Cite this Article
    Zhilei LI, Haifeng LIU, Weiwei CHI, Limei ZHOU, Fang XIE, Yangyang LIU. Design and application of optical system based on terahertz spectroscopy technology[J]. Journal of Applied Optics, 2022, 43(3): 409 Copy Citation Text show less
    Structure parameters of plano-convex lens
    Fig. 1. Structure parameters of plano-convex lens
    Size of focused spot on single lens
    Fig. 2. Size of focused spot on single lens
    Terahertz beam shaping optical system
    Fig. 3. Terahertz beam shaping optical system
    Size of focused spot on sample surface
    Fig. 4. Size of focused spot on sample surface
    Terahertz spectrum test
    Fig. 5. Terahertz spectrum test
    Terahertz time-domain and frequency-domain signals
    Fig. 6. Terahertz time-domain and frequency-domain signals
    Frequency-domain curves about refractive index and absorption coefficient of moxifloxacin hydrochloride and levofloxacin
    Fig. 7. Frequency-domain curves about refractive index and absorption coefficient of moxifloxacin hydrochloride and levofloxacin
    参数优化前优化后
    r/mm 17.5517.55
    d/mm 9.59.5
    c/mm 2827.315
    k0−0.574
    l/mm 5052.641
    Table 1. Optimization parameters of plano-convex lens
    Zhilei LI, Haifeng LIU, Weiwei CHI, Limei ZHOU, Fang XIE, Yangyang LIU. Design and application of optical system based on terahertz spectroscopy technology[J]. Journal of Applied Optics, 2022, 43(3): 409
    Download Citation