• Journal of Innovative Optical Health Sciences
  • Vol. 10, Issue 1, 1650029 (2017)
Jiemei Chen1, Tian Ai1, Tao Pan2、*, Lijun Yao2, and Fenggeng Xia3
Author Affiliations
  • 1Department of Biological Engineering, Jinan University, Huangpu Road West 601 Tianhe District, Guangzhou 510632, P. R. China
  • 2Department of Optoelectronic Engineering, Jinan University, Huangpu Road West 601, Tianhe District, Guangzhou 510632, P. R. China
  • 3Guangzhou Institutes of Microbiology, Jian Tashan Road 1, Science City, Luogang District, Guangzhou 510530, P. R. China
  • show less
    DOI: 10.1142/s1793545816500292 Cite this Article
    Jiemei Chen, Tian Ai, Tao Pan, Lijun Yao, Fenggeng Xia. AO–MW–PLS method applied to rapid quantification of teicoplanin with near-infrared spectroscopy[J]. Journal of Innovative Optical Health Sciences, 2017, 10(1): 1650029 Copy Citation Text show less

    Abstract

    Teicoplanin (TCP) is an important lipoglycopeptide antibiotic produced by fermenting Acti-noplanes teichomyceticus. The change in TCP concentration is important to measure in the fermentation process. In this study, a reagent-free and rapid quantification method for TCP in the TCP–Tris–HCl mixture samples was developed using near-infrared (NIR) spectroscopy by focusing our attention on the fermentation process for TCP. The absorbance optimization (AO) partial least squares (PLS) was proposed and integrated with the moving window (MW) PLS, which is called AO–MW–PLS method, to select appropriate wavebands. A model set that includes various wavebands that were equivalent to the optimal AO–MW–PLS waveband was proposed based on statistical considerations. The public region of all equivalent wavebands was just one of the equivalent wavebands. The obtained public regions were 1540–1868 nm for TCP and 1114–1310 nm for Tris. The root-mean-square error and correlation coefficient for leave-one-out cross validation were 0.046 mg mL 1 and 0.9998 mg mL 1 for TCP, and 0.235 mg mL 1 and 0.9986 mg mL 1 for Tris, respectively. All the models achieved highly accurate prediction effects, and the selected wavebands provided valuable references for designing specialized spectrometers. This study provided a valuable reference for further application of the proposed methods to TCP fermentation broth and to other spectroscopic analysis fields.
    Jiemei Chen, Tian Ai, Tao Pan, Lijun Yao, Fenggeng Xia. AO–MW–PLS method applied to rapid quantification of teicoplanin with near-infrared spectroscopy[J]. Journal of Innovative Optical Health Sciences, 2017, 10(1): 1650029
    Download Citation