• Journal of Innovative Optical Health Sciences
  • Vol. 12, Issue 6, 1950017 (2019)
V. A. Ushenko1, A. Yu. Sdobnov2, W. D. Mishalov3, A. V. Dubolazov1、4、*, O. V. Olar1, V. T. Bachinskyi5, A. G. Ushenko1, Yu. A. Ushenko1, O. Ya. Wanchuliak5, and I. Meglinski2、6、7、8
Author Affiliations
  • 1Chernivtsi National University 2 Kotsiubynskyi St., Chernivtsi, 58012 Ukraine
  • 2Faculty of Information Technology and Electrical Engineering University of Oulu, Oulu 90570, Finland
  • 3Shupyk National Medical Academy of Postgraduate Education 9, Dorogozhytska St., Kyiv, 04112 Ukraine
  • 4Aston Institute of Materials Research School of Engineering and Applied Science Aston University, Birmingham, B4 7ET, UK
  • 5Bukovinian State Medical University 3 Theatral Sq., Chernivtsi, 58000 Ukraine
  • 6Interdisciplinary Laboratory of Biophotonics National Research Tomsk State University Tomsk, 634050 Russia
  • 7Institute of Engineering Physics for Biomedicine (PhysBio) National Research Nuclear University "MEPhI" Moscow, 15409 Russia
  • 8School of Life and Health Sciences, Aston University Birmingham, B4 7ET, UK
  • show less
    DOI: 10.1142/s1793545819500172 Cite this Article
    V. A. Ushenko, A. Yu. Sdobnov, W. D. Mishalov, A. V. Dubolazov, O. V. Olar, V. T. Bachinskyi, A. G. Ushenko, Yu. A. Ushenko, O. Ya. Wanchuliak, I. Meglinski. Biomedical applications of Jones-matrix tomography to polycrystalline films of biological fluids[J]. Journal of Innovative Optical Health Sciences, 2019, 12(6): 1950017 Copy Citation Text show less

    Abstract

    Algorithms for reconstruction of linear and circular birefringence-dichroism of optically thin anisotropic biological layers are presented. The technique of Jones-matrix tomography of polycrystalline films of biological fluids of various human organs has been developed and experimentally tested. The coordinate distributions of phase and amplitude anisotropy of bile films and synovial fluid taken from the knee joint are determined and statistically analyzed. Criteria (statistical moments of 3rd and 4th orders) of Differential diagnostics of early stages of cholelithiasis and septic arthritis of the knee joint with excellent balanced accuracy were determined. Data on the diagnostic efficiency of the Jones-matrix tomography method for polycrystalline plasma (liver disease), urine (albuminuria) and cytological smears (cervical cancer) are presented.
    V. A. Ushenko, A. Yu. Sdobnov, W. D. Mishalov, A. V. Dubolazov, O. V. Olar, V. T. Bachinskyi, A. G. Ushenko, Yu. A. Ushenko, O. Ya. Wanchuliak, I. Meglinski. Biomedical applications of Jones-matrix tomography to polycrystalline films of biological fluids[J]. Journal of Innovative Optical Health Sciences, 2019, 12(6): 1950017
    Download Citation