• Acta Photonica Sinica
  • Vol. 41, Issue 2, 185 (2012)
WANG Yi-qun1,2,*, YAN Chang-xiang1, and JIA Ping1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/gzxb20124102.0185 Cite this Article
    WANG Yi-qun, YAN Chang-xiang, JIA Ping. Motion Precision Measurement of Imaging Spectrometer′s Scanning Mirror[J]. Acta Photonica Sinica, 2012, 41(2): 185 Copy Citation Text show less
    References

    [1] ECKARDT A, SKRBEK W, HOFER S, et al. SNR estimation for advanced hyperspectral space instrument[C]. SPIE, 2005, 5883: 1-7.

    [2] SELLAR R G, BOREMAN G D. Comparison of relative signal-to-noise ratios of different classes of imaging spectrometer[J]. Applied Optics, 2005, 44(9): 1614-1624.

    [3] NIEKE J, SOLBRIG M, NEUMANN A. Noise contributions for imaging spectrometers[J]. Applied Optics, 1999, 38(24): 5191-5194.

    [4] SCHUMANN L W, LOMHEIM T S. Infrared hyperspectral imaging fourier transform and dispersive spetrometers: comparison of signal-to-noise based performance[C]. SPIE, 2002, 4480: 1.

    [5] LI Huan, XIANG Yang, FENG Yu-tao. Ground resolution for imaging spectrometer with motion compensation[J]. Optics and Precision Engineering, 2009, 17(4): 745-747.

    [6] LI You-ping, YU Bing-xi, HAN Chang-yuan, et al. Tradeoff optimization design of optical configuration on imaging spectrometer[J]. Optics and Precision Engineering, 2006, 14(6): 975-976.

    [7] PEARLMAN J, SEGAL C, LIAO L. Development and operation of the EO-1 hyperion imaging spectrometer[C]. SPIE, 2004, 4135: 243-253.

    [8] FENG Yu-tao, XIANG Yang, CHEN Xu. The characteristics of spectral radiance measured by imaging spectrometer with motion compensation[J]. Infrared Technology, 2009, 31(2): 107-109.

    [9] YAN De-jie, HAN Cheng-shan, LI Wei-xiong. Optimization design of scroll and pitch and their control errors on aerocraft[J]. Optics and Precision Engineering, 2009, 17(9): 2226-2227.

    CLP Journals

    [1] CHEN Wei, ZHENG Yu-quan, XUE Qing-sheng. Optical System Design of Airborne Wide Field-of-view Hyperspectral Imager[J]. Acta Photonica Sinica, 2014, 43(10): 1022001

    [2] Hu Chunhui, Yan Changxiang, Shao Jianbing. Pointing Mirror Low Frequency Sine Oscillation Induced Remote Sensor Image Distortion and Correction[J]. Acta Optica Sinica, 2013, 33(4): 428002

    [3] GAO Zhi-fan, ZHANG Hong-ping, WU Qiong-shui, ZENG Li-bo. Calibration and Characterization of an AOTF-based Hyperspectral Imaging System[J]. Acta Photonica Sinica, 2015, 44(7): 711001

    [4] LUO Yongjun, MOU Tongsheng. Design of a Weighted Radiance of the LED Measuring System[J]. Acta Photonica Sinica, 2013, 42(12): 1496

    [5] YANG Wei-fan, XU Shu-yan, CAO Xiao-tao, WANG Dong. Design of scanning control system for space optical remote sensor[J]. Optics and Precision Engineering, 2014, 22(2): 397

    [6] Wang Yang, Yan Changxiang, Zhang Da, Wang Yiqun, Gao Zhiliang, Liu Dongbin. Error Analysis for the Non-Contact Measuring System of Pointing Mirror[J]. Acta Optica Sinica, 2013, 33(10): 1012001

    WANG Yi-qun, YAN Chang-xiang, JIA Ping. Motion Precision Measurement of Imaging Spectrometer′s Scanning Mirror[J]. Acta Photonica Sinica, 2012, 41(2): 185
    Download Citation