• Acta Photonica Sinica
  • Vol. 40, Issue 4, 627 (2011)
XIA Tian1、2、*, ZHANG Xue-long3, MA Jun-shan1, CHENG Jing-hai3, and HUANG Yong3
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less
    DOI: Cite this Article
    XIA Tian, ZHANG Xue-long, MA Jun-shan, CHENG Jing-hai, HUANG Yong. Effect of Spatial Coherence and in Incident X-ray Photon Energies on Clinical X-ray In-line Phase-contrast Imaging[J]. Acta Photonica Sinica, 2011, 40(4): 627 Copy Citation Text show less
    References

    [1] POGANY A, GAO D, WILKINS S W. Contrast and resolution in imaging with a microfocus X-ray source[J]. Review of Scientific Instruments, 1997, 68(7): 2774-2782.

    [2] MOMOSE A, TAKEDA T, ITAI Y. Phase-contrast x-ray computed tomography for observing biological specimens and organic materials[J]. Review of Scientific Instruments, 1995, 66(2): 1434-1436.

    [3] YONEYAMA A, TAKEDA T, TSUCHIYA Y, et al. Coherence-contrast X-ray imaging based on X-ray interferometry[J]. Applied Optics, 2005, 44(16): 3258-3261.

    [4] PFEIFFER F, BUNK O, DAVID C, et al. High-resolution brain tumor visualization using three-dimensional X-ray phase contrast tomography[J]. Physics in Medicine and Biology, 2007, 52: 6923-6930.

    [5] DAVIS T J, GAO D, GUREYEV T E, et al. Phase contrast imaging of weakly absorbing materials using hard X-rays[J]. Nature, 1995, 373(16): 595-598.

    [6] KOBAYASHI K, IZUMI K, KIMURA H, et al. X-ray phase-contrast imaging with submicron resolution by using extremely asymmetric Bragg diffractions[J]. Applied Physics Letters, 2001, 78(1): 132-134.

    [7] MENK R H, RIGON L, ARFELLI F. Diffraction-enhanced X-ray medical imaging at the ELETTRA synchrotron light source[J]. Nuclear Instruments and Methods in Physics Research Secti A, 2005, 548: 213-220.

    [8] GUIGAY J P, PAGOT E, CLOETENS P. Fourier optics approach to X-ray analyzer-based imaging[J]. Opt Commun, 2007, 270(2): 180-188.

    [9] WU Xi-zeng , LIU Hong. A general theoretical formalism for X-ray phase contrast imaging[J]. Journal of X-ray Science and Technology, 2003, 11(1): 33-42.

    [10] GUREYEV T E, NESTERETS Y I, PAGANIN D M, et al. Effects of incident illumination on in-line phase-contrast imaging[J]. JOSA A, 2006, 23(1): 34-42.

    [11] WU Xi-zeng, LIU Hong. Clinical implementation of X-ray phase contrast imaging: theoretical foundation and design consideration[J]. Medical Physics, 2003, 30(8): 2169-2179.

    [12] ZHANG Xue-long, LIU Song, HUANG Yong, et al. Optimal Contrast for X-ray Phase-contrast imaging. Acta Photonica Sinica, 2008, 37(6): 1217-1220.

    [13] XIA Tian, ZHANG Xue-long, ZHANG Guo-ying. Analysis of the absorption and the phase-effect on micro-focus X-PCI[J]. Acta Photonica Sinica, 2009, 38(10): 2516-2160.

    [14] WU X Z, DEAN A, LIU H. X-ray diagnostic techniques biomedical photonics handbook[M]. Tampa, FL: CRC Press, 2003: 1116.

    [15] SNIGIREV A, SNIGIREVA I, KOHN V, et al. On the possibilities of X-ray phase contrast microimaging by coherent high-energy synchrotron radiation[J]. Scientific Instruments, 1995, 66(12): 5486-5492.

    [16] WILKINS S, GUREYEV T, GAO D, et al. Phase-contrast imaging using polychromatic hard x-rays[J]. Nature, 1996, 384(28): 335-338.

    [17] BORN M, WOLF E. Principles of optics: electromagnetic theory of propagation, interference and diffraction of light[M]. 7th ed. Cambridge, England: Cambridge University Press, 1999.

    [18] ATTWOOD D T. Soft X-ray and extreme ultraviolet radiation: principles and application[M]. Cambridge:Cambridge University Press,1999.

    [19] WU X Z, LIU H, YAN A. Optimization of X-ray phase-contrast imaging based on in-line holography[J]. Nuclear Instruments and Methods in Physics Research Section B, 2005, 234(4): 563-572.

    [20] WU X Z, LIU H. An experimental method of determining relative phase- contrast factor for X-ray imaging systems[J]. Medical Physics, 2004, 31: 997-1002.

    CLP Journals

    [1] [in Chinese], [in Chinese], [in Chinese], WALI Faiz. Fabrication of X-ray Absorption Gratings by Free Settling of Bismuth Nanoparticles[J]. Acta Photonica Sinica, 2019, 48(10): 1005001

    [2] MA Qing-li, TANG Shi-biao, WU Yan-hua. Point Spread Function of Pinhole Imaging System for Deviating from Center of Incident γ-Ray[J]. Acta Photonica Sinica, 2015, 44(3): 311004

    XIA Tian, ZHANG Xue-long, MA Jun-shan, CHENG Jing-hai, HUANG Yong. Effect of Spatial Coherence and in Incident X-ray Photon Energies on Clinical X-ray In-line Phase-contrast Imaging[J]. Acta Photonica Sinica, 2011, 40(4): 627
    Download Citation