• Optics and Precision Engineering
  • Vol. 15, Issue 10, 1489 (2007)
and
Author Affiliations
  • [in Chinese]
  • show less
    DOI: Cite this Article
    [in Chinese], [in Chinese]. Effect of axial temperature difference on imaging quality of space remote sensor optical system[J]. Optics and Precision Engineering, 2007, 15(10): 1489 Copy Citation Text show less
    References

    [1] FORMAN S E,SULTANA J A.Evaluation of mirror thermal distortion from temperature measurements[J].SPIE,1990,1303:65-77.

    [2] BELY P Y.Space Ten-Meter Telescope(STMT) structral and thermal feasibility study of the primary mirror[J].SPIE,1987,751:29-36.

    [5] SMITH W J.Modern Optical Engineering:the Design of the Optical System[M].(Second Edition)McGrawHILL,Inc,1990.

    CLP Journals

    [1] JIANG Wen-tao, LI Guo-zhang, REN Guo-quan, LI Dong-wei, CHEN Cheng. Simulation of Temperature Influence on Imaging Quality of Vehicle-Mounted Sight[J]. Electronics Optics & Control, 2015, 22(12): 80

    [2] Zhang Xuemin, Han Juan, Duan Jiayou, Wu Mengyuan, Wei Ruyi. Alignment Method of Coaxial Eccentric-Pupil Three-Mirror System[J]. Chinese Journal of Lasers, 2012, 39(4): 416003

    [3] LIU Xiang-yi, ZHANG Jing-xu, WU Xiao-xia, LI Jian-feng, SUN Jing-wei. Affect of environment on mirror seeing of large-aperture SiC lightweight primary mirror[J]. Optics and Precision Engineering, 2015, 23(3): 776

    [4] HAN Xu, MA Jun, LI Ming, FU Yue-gang, WANG Jia-ke. Temperature adaptation of mapping camera[J]. Optics and Precision Engineering, 2012, 20(6): 1175

    [5] WU Ming-chang, YANG Shi-mo, CHEN Zhi-yuan, GU Xue-dong, WANG Shen. Thermo-optical testing of Hα and white telescope[J]. Optics and Precision Engineering, 2009, 17(7): 1519

    [6] Wu Xiao-xia, WANG Ming-hao, MING Ming, WANG Fu-guo. Calibration of thermal distortion for large aperture SiC lightweight mirror[J]. Optics and Precision Engineering, 2012, 20(6): 1243

    [7] Gong Dun, Wang Hong, Tian Tieyin. Temperature Effect on Imaging Performance of Three-Line CCD Satellite Camera and Temperature Indicators Affirmed[J]. Acta Optica Sinica, 2010, 30(7): 2017

    [8] CHEN Hao, XUAN Li, HU Li-fa, CAO Zhao-liang, MU Quan-quan. Design of open-loop liquid crystal adaptive optical system for 1 200 mm telescope[J]. Optics and Precision Engineering, 2010, 18(1): 29

    [in Chinese], [in Chinese]. Effect of axial temperature difference on imaging quality of space remote sensor optical system[J]. Optics and Precision Engineering, 2007, 15(10): 1489
    Download Citation