    Abstract

    The characteristics of a computerized radiography system were briefly discussed. The method for X-ray image digitalization was introduced. The hardware circuit for X-ray image data acquistion was given. Architecture of Windows NT and its kernal mode driver were briefly illustrated, and the working principle of I/O request in Windows NT was interpreted. The kernel mode driver for the X-ray image data acquisition card was designed with NT DDK. The real-time acquisition and storing of X-ray image data were carried out by the combination of hardware and software. In the long-term experiment, it has been proved that the method is feasible and reliable, and it can meet the practical commands.