• Frontiers of Optoelectronics
  • Vol. 6, Issue 2, 185 (2013)
Kaushik BRAHMACHARI and Mina RAY*
Author Affiliations
  • Department of Applied Optics and Photonics, University of Calcutta, Kolkata 700 009, India
  • show less
    DOI: 10.1007/s12200-013-0313-2 Cite this Article
    Kaushik BRAHMACHARI, Mina RAY. Effect of prism material on design of surface plasmon resonance sensor by admittance loci method[J]. Frontiers of Optoelectronics, 2013, 6(2): 185 Copy Citation Text show less
    References

    [1] Otto A. Excitation of nonradiative surface plasma waves in silver by the method of frustrated total reflection. Zeitschrift fur Physik, 1968, 216(4): 398-410

    [2] Kretschmann E, Raether H. Radiative decay of non-radiative surface plasmons excited by light. Zeitschrift fur Naturforschung. Teil B. Anorganische Chemie, Organische Chemie, Biochemie, Biophysik, Biologie, 1968, 23A: 2135-2136

    [3] Liedberg B, Nylander C, Lunstrom I. Surface plasmon resonance for gas detection and biosensing. Sensors and Actuators, 1983, 4: 299-304

    [4] Homola J, Yee S S, Gauglitz G. Surface plasmon resonance sensor: review. Sensors and Actuators B, Chemical, 1994, 54(1-2): 3-15

    [5] Homola J, Koudela I, Yee S S. Surface plasmon resonance sensors based on diffraction gratings and prism couplers: sensitivity comparison. Sensors and Actuators B, Chemical, 1999, 54(1-2): 16-24

    [6] Brahmachari K, Ghosh S, Ray M. Experimental observation of surface plasmon resonance using various geometrical configurations of metal-dielectric interface. In: Proceedings of the International symposium on Advances in Nanomaterials, CSIR-Central Glass & Ceramic Research Institute, Kolkata, India, 2010

    [7] Ghosh S, Brahmachari K, Ray M. Experimental investigation of surface plasmon resonance using a chemically deposited silver film on a tapered cylindrical glass rod. In: Proceedings of the International Conference on Specialty Glass & Optical Fiber: Materials, Technology & Devices, CSIR-Central Glass & Ceramic Research Institute, Kolkata, India, 2011

    [8] Ghosh S, Brahmachari K, Ray M. Experimental investigation of surface plasmon resonance using tapered cylindrical light guides with metal-dielectric interface. Journal of Sensor Technology, 2012, 2(1): 48-54

    [9] Macleod A H. Thin-Film Optical Filters. 4th ed. New York: CRC Press, 2010

    [10] Lin W C, Chen P K, Su C M, Lee K C, Yang C C. Bio-plasmonics: nano/micro structure of surface plasmon resonance devices for biomedicine. Optical and Quantum Electronics, 2005, 37(13-15): 1423-1437

    [11] Lin W C, Chen P K, Su C M, Hsiao C T, Lee S S, Lin S, Shi J X, Lee K C. Admittance loci design method for multilayer surface plasmon resonance devices. Sensors and Actuators B, Chemical, 2006, 117(1): 219-229

    [12] Lin W C, Chen P K, Hsiao N C, Lin S, Lee K C. Design and fabrication of an alternating dielectric multi-layer device for surface plasmon resonance sensor. Sensors and Actuators B, Chemical, 2006, 113(1): 169-176

    [13] Jen Y J, Lakhtakia A, Yu C W, Chan T Y. Multilayered structures for p- and s-polarized long-range surface-plasmon-polariton propagation. Journal of the Optical Society of America A, Optics, Image Science, and Vision, 2009, 26(12): 2600-2606

    [14] Brahmachari K, Ghosh S, Ray M. Application of admittance loci method in surface plasmon resonance technology for sensing of different chemical and biological samples. In: Proceedings of the International Conference on Specialty Glass & Optical Fiber: Materials, Technology & Devices, CSIR-Central Glass & Ceramic Research Institute, Kolkata, India, 2011

    [15] Brahmachari K, Ghosh S, Ray M. Substrate dependence of surface plasmon resonance sensor with a multilayer structure using admittance loci method. In: Proceedings of 2nd International Conference on Trends in Optics and Photonics, Kolkata, India, 2011, 402-407

    [16] Brahmachari K, Ghosh S, Ray M. Surface plasmon resonance based sensing of different chemical and biological samples using admittance loci method. Photonic Sensors, 2012, doi:10.1007/s13320-012-0062-7

    [17] Chen Y, Ming H. Review of surface plasmon resonance and localized surface plasmon resonance sensor. Photonic Sensors, 2012, 2(1): 37-49

    [18] Micheletto R, Hamamoto K, Fuji T, Kawakami Y. Tenfold improved sensitivity using high refractive-index substrates for surface plasmon sensing. Applied Physics Letters, 2008, 93(17): 1741041-1741043

    [19] Gupta G, Kondoh J. Tuning and sensitivity enhancement of surface plasmon resonance sensor. Sensors and Actuators B, Chemical, 2007, 122(2): 381-388

    Kaushik BRAHMACHARI, Mina RAY. Effect of prism material on design of surface plasmon resonance sensor by admittance loci method[J]. Frontiers of Optoelectronics, 2013, 6(2): 185
    Download Citation