• Chinese Optics Letters
  • Vol. 21, Issue 1, 011202 (2023)
Yongjian Li1, Shuai Zhang1, Jinyi Li2, Xiaotao Yang3, Yunfei Meng1, Xu Liu1, and Zhenhui Du1、*
Author Affiliations
  • 1State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
  • 2Tianjin Key Laboratory of Intelligent Control of Electrical Equipment, Tiangong University, Tianjin 300387, China
  • 3College of Power and Energy Engineering, Harbin Engineering University, Harbin 150001, China
  • show less
    DOI: 10.3788/COL202321.011202 Cite this Article Set citation alerts
    Yongjian Li, Shuai Zhang, Jinyi Li, Xiaotao Yang, Yunfei Meng, Xu Liu, Zhenhui Du. Preliminary study on direct measurements and diagnostics for chemical reaction dynamics of NOx by using laser wavelength modulation spectroscopy[J]. Chinese Optics Letters, 2023, 21(1): 011202 Copy Citation Text show less
    Schematic diagram of the experimental system: (a) NOx measurement modulation waveform; (b) O2 measurement modulation waveform; (c) WMS-2f/1f signal of demodulated O2 absorption spectra; (d) WMS-2f/1f signal of demodulated NO and NO2 absorption spectra.
    Fig. 1. Schematic diagram of the experimental system: (a) NOx measurement modulation waveform; (b) O2 measurement modulation waveform; (c) WMS-2f/1f signal of demodulated O2 absorption spectra; (d) WMS-2f/1f signal of demodulated NO and NO2 absorption spectra.
    Fitting results and residuals of WMS-2f/1f for NO2, NO, and O2 absorption spectra: (a) 0.14% relative root mean square (RMS) for the NO2 spectra; (b) 0.17% relative RMS for the NO spectra; (c) 0.21% relative RMS for the O2 spectra.
    Fig. 2. Fitting results and residuals of WMS-2f/1f for NO2, NO, and O2 absorption spectra: (a) 0.14% relative root mean square (RMS) for the NO2 spectra; (b) 0.17% relative RMS for the NO spectra; (c) 0.21% relative RMS for the O2 spectra.
    Measurement results of O3 oxidizing NO reaction process: (a) temperature; (b) pressure; (c) NO2 concentration; (d) NO concentration; (e) O2 concentration; (f) O3 concentration; (g) denitrification rate.
    Fig. 3. Measurement results of O3 oxidizing NO reaction process: (a) temperature; (b) pressure; (c) NO2 concentration; (d) NO concentration; (e) O2 concentration; (f) O3 concentration; (g) denitrification rate.
    GasLaserMeasurement MethodWavenumber (cm−1)Detection Sensitivity (mol/L)
    O2DBR, PhotodigmWMS-2f/1f13142.66.13×106
    NO2QCL, HamamatsuWMS-2f/1f1629.854.91×106
    1630.33
    NOQCL, HamamatsuWMS-2f/1f1900.071.06×105
    O3Electrochemical4.09×106
    Table 1. Experimental System Configuration Parameters
    Yongjian Li, Shuai Zhang, Jinyi Li, Xiaotao Yang, Yunfei Meng, Xu Liu, Zhenhui Du. Preliminary study on direct measurements and diagnostics for chemical reaction dynamics of NOx by using laser wavelength modulation spectroscopy[J]. Chinese Optics Letters, 2023, 21(1): 011202
    Download Citation