• Acta Physica Sinica
  • Vol. 68, Issue 2, 024203-1 (2019)
Yu-Long Yin1、2、3、*, Xiao-Bing Sun1、3、*, Mao-Xin Song1、3, Wei Chen1、2、3, and Fei-Nan Chen1、3
Author Affiliations
  • 1Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China
  • 2University of Science and Technology of China, Hefei 230026, China
  • 3Key Laboratory of Optical Calibration and Characterization, Chinese Academy of Sciences, Hefei 230031, China
  • show less
    DOI: 10.7498/aps.68.20181553 Cite this Article
    Yu-Long Yin, Xiao-Bing Sun, Mao-Xin Song, Wei Chen, Fei-Nan Chen. Phase delay error analysis of wave plate of division-of-amplitude full Stokes simultaneous polarization imaging system[J]. Acta Physica Sinica, 2019, 68(2): 024203-1 Copy Citation Text show less

    Abstract

    The division-of-amplitude full Stokes simultaneous polarization imaging system has prominent merits, such as real time, high spatial resolution, high precision, etc. The development of the division-of-amplitude full Stokes simultaneous polarization imaging system has a high application value. The division-of-amplitude full Stokes simultaneous polarization imaging system uses polarization beam splitters, a half wave plate (HWP) and a quarter wave plate (QWP) to modulate the incident Stokes vector into four intensity images. Using the four intensity images, the incident Stokes vector can be analyzed. In the system, the phase delay errors of the HWP and the QWP have a direct influence on the measurement accuracy of the incident Stokes vector. A Stokes vector measurement error equation containing the phase delay errors of the HWP and the QWP is established. When there are the phase delay errors of the HWP and the QWP in the system, the Stokes vector measurement errors of the unpolarized light, 0° liner polarized light, 90° liner polarized light, 45° liner polarized light, 135° liner polarized light, right circularly polarized light and left circularly polarized light are analyzed. A method of solving the Stokes vector measurement error of incident light with any polarization state is given. When the Stokes vectors with different degrees of polarization (DOPs) are used as the incident light, the simulation results show that both the Stokes vector measurement error and the DOP measurement error increase with the DOP of incident light increasing. Therefore, we select the polarization measurement accuracy to evaluate the system when the DOP of incident light equals 1. To ensure that the polarization measurement accuracy of the system is within 2%, the phase delay error of the HWP should be within ±1.6° and the phase delay error of the QWP should be within ±0.5°. The analysis results of the phase delay errors of the HWP and the QWP are of great significance for improving the polarization measurement accuracy of the division-of-amplitude full Stokes simultaneous polarization imaging system, and also provide important theoretical guidance in designing and developing the system.
    Yu-Long Yin, Xiao-Bing Sun, Mao-Xin Song, Wei Chen, Fei-Nan Chen. Phase delay error analysis of wave plate of division-of-amplitude full Stokes simultaneous polarization imaging system[J]. Acta Physica Sinica, 2019, 68(2): 024203-1
    Download Citation