• NUCLEAR TECHNIQUES
  • Vol. 47, Issue 10, 100404 (2024)
Yang ZHAO, Xie WANG, Binyuan XIA, Shuo LI..., Liang WANG, Weiying PENG, Kezhao LIU and Zhonghua XIONG*|Show fewer author(s)
Author Affiliations
  • Institute of Material Research, China Academy of Engineering Physics, Mianyang 621700, China
  • show less
    DOI: 10.11889/j.0253-3219.2024.hjs.47.100404 Cite this Article
    Yang ZHAO, Xie WANG, Binyuan XIA, Shuo LI, Liang WANG, Weiying PENG, Kezhao LIU, Zhonghua XIONG. Sensitization effects of CR-39 neutron dosimeters pre-treated with CO2 under various pressures and durations[J]. NUCLEAR TECHNIQUES, 2024, 47(10): 100404 Copy Citation Text show less
    References

    [1] Sohrabi M. On different methods of measuring neutron dose/fluence generated during radiation therapy with megavoltage beams[J]. Health Physics, 119, 368-370(2020).

    [2] Bolzonella M, Ambrožová I, Caresana M et al. Neutron personal dosimetry using polyallyl diglycol carbonate (PADC): Current status, best practices and proposed research[J]. Physics Open, 12, 100114(2022).

    [3] Gómez-Ros J M, Bedogni R, Domingo C. Personal neutron dosimetry: State-of-the-art and new technologies[J]. Radiation Measurements, 161, 106908(2023).

    [4] D'Errico F, Weiss M, Luszik-Bhadra M et al. A CR-39 track image analyser for neutron spectrometry[J]. Radiation Measurements, 28, 823-830(1997).

    [5] Guo S L, Chen B L, Durrani S A[M]. Handbook of radioactivity analysis (4th ed): Chapter 3 Solid-state nuclear track detectors, 307-407(2020).

    [6] Hulber E, Selmeczi D. Counting recoil proton tracks on PADC without a pre-etching step. A novel approach for neutron dosimeter application[J]. Radiation Measurements, 40, 616-619(2005).

    [7] WANG Liqin, QU Ximei, JIAO Ling et al. New progress of etching technology for CR-39 solid state nuclear track detector[J]. Nuclear Techniques, 35, 863-868(2012).

    [8] Fujii M, Yokota R, Kobayashi T et al. Sensitization of polymeric track detectors with carbon dioxide[J]. Radiation Measurements, 25, 141-144(1995).

    [9] Fujii M, Yokota R, Kobayashi T et al. Effect of vacuum, oxygen and carbon dioxide on the track registration in SR-90 and CR-39[J]. Radiation Measurements, 28, 61-64(1997).

    [10] Csige I. Post-irradiation sensitization of CR-39 track detector in carbon dioxide atmosphere[J]. Radiation Measurements, 28, 171-176(1997).

    [11] Janik M, Hasan M M, Bossew P et al. Effects of storage time and pre-etching treatment of CR-39 detectors on their response to alpha radiation exposure[J]. International Journal of Environmental Research and Public Health, 18, 8346(2021).

    [12] Saad A F, Atwa S T, Yasuda N et al. FT-IR spectroscopy of carbon dioxide in CR-39 and SR-90 track detectors irradiated with ions and gamma-rays at different energies and fluences[J]. Radiation Measurements, 34, 51-54(2001).

    [13] D'Errico F, de Vasconcelos D A A, Ciolini R et al. Track size distributions in CR-39 neutron dosimeters treated with carbon dioxide[J]. Radiation Measurements, 106, 607-611(2017).

    [14] Kazumasa S, Takuya A, Takeshi I et al. Sensitization of solid state nuclear track detector in carbon dioxide for improved fast neutron dosimeter[J]. Japanese Journal of Health Physics, 46, 163-167(2011).

    [16] Yamauchi T, Mori Y, Chikada H et al. Sensitization of PADC track detector in carbon dioxide gas[J]. Radiation Measurements, 44, 1105-1108(2009).

    [17] Cantor B[M]. The equations of materials: Chapter 7 fick's laws: diffusion, 141-161(2020).

    [18] LI Yang, XIA Xiaobin, CAO Zhen et al. An experimental study on optimal chemical etching condition for CR-39 used in neutron detection[J]. Nuclear Techniques, 39, 060402(2016).

    [20] Kodaira S, Nanjo D, Kawashima H et al. Mass spectrometry analysis of etch products from CR-39 plastic irradiated by heavy ions[J]. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 286, 229-232(2012).

    [21] Awad E M, Rana MA, Al-Jubbori M A. Bulk etch rates of CR-39 at high etchant concentrations: diffusion-limited etching[J]. Nuclear Science and Technology, 31, 118(2020).

    [22] Hassan N M, Matai Y, Kusumoto T et al. On the mechanism of the sensitization of PADC (poly(allyl diglycol carbonate)) track detectors by carbon dioxide treatment[J]. Radiation Measurements, 59, 23-29(2013).

    [23] Tanner R J, Bartlett D T, Hager L G. Operational and dosimetric characteristics of etched-track neutron detectors in routine neutron radiation protection dosimetry[J]. Radiation Measurements, 40, 549-559(2005).

    [24] Jakes J, Voigt J, Schraube H. Evaluation of the CR-39 response on the basis of track-size distributions[J]. Radiation Measurements, 25, 437-440(1995).

    [25] Jakes J, Voigt J, Schraube H. Etched track size distributions induced by broad neutron spectra in PADC[J]. Radiation Protection Dosimetry, 70, 133-138(1997).

    [26] Phillips G W, Spann J E, Bogard J S et al. Neutron spectrometry using CR-39 track etch detectors[J]. Radiation Protection Dosimetry, 120, 457-460(2006).

    [27] Hulber E. Overview of PADC nuclear track readers. Recent trends and solutions[J]. Radiation Measurements, 44, 821-825(2009).

    [30] Li Z L, Zhuo W H, He Y L et al. Estimation of energy and angle of incident protons from three-dimensional track profiles on CR-39 detectors[J]. Radiation Measurements, 150, 106694(2022).

    Yang ZHAO, Xie WANG, Binyuan XIA, Shuo LI, Liang WANG, Weiying PENG, Kezhao LIU, Zhonghua XIONG. Sensitization effects of CR-39 neutron dosimeters pre-treated with CO2 under various pressures and durations[J]. NUCLEAR TECHNIQUES, 2024, 47(10): 100404
    Download Citation