• High Power Laser and Particle Beams
  • Vol. 32, Issue 5, 055002 (2020)
Linshen Xie, Wei Wu, and Xiangqin Zhu
Author Affiliations
  • State Key Laboratory of Intense Pulsed Radiation Simulation and Effect (Northwest Institute of Nuclear Technology), Xi’an 710024, China
  • show less
    DOI: 10.11884/HPLPB202032.190434 Cite this Article
    Linshen Xie, Wei Wu, Xiangqin Zhu. Regularity analysis of leakage-field from vertically polarized bounded wave electromagnetic pulse simulator with distributed load[J]. High Power Laser and Particle Beams, 2020, 32(5): 055002 Copy Citation Text show less
    Configuration of bounded-wave EMP simulator with distributed load
    Fig. 1. Configuration of bounded-wave EMP simulator with distributed load
    Comparison of results got from simulation and experiment
    Fig. 2. Comparison of results got from simulation and experiment
    Comparison of relative peak-values of leakage electric fields got from simulation and experiment
    Fig. 3. Comparison of relative peak-values of leakage electric fields got from simulation and experiment
    Comparison of relative peak-values of leakage field(Ez) at different horizontal plane with various hd
    Fig. 4. Comparison of relative peak-values of leakage field(Ez) at different horizontal plane with various hd
    Comparison of relative peak-values of leakage field at different horizontal plane with various hd
    Fig. 5. Comparison of relative peak-values of leakage field at different horizontal plane with various hd
    Comparison of relative peak-values of leakage field at different location
    Fig. 6. Comparison of relative peak-values of leakage field at different location
    Comparison of relative peak-values of leakage field as exciting source changes
    Fig. 7. Comparison of relative peak-values of leakage field as exciting source changes
    Comparison of leakage field from simulator as εr of ground changes
    Fig. 8. Comparison of leakage field from simulator as εr of ground changes
    Comparison of relative peak-values of leakage field as electronic conductivity of ground changes
    Fig. 9. Comparison of relative peak-values of leakage field as electronic conductivity of ground changes
    tr/ns FWHM/nsrelative peak-values of leakage field
    ABCDE
    1.0200.4150.4240.3610.2440.310
    2.5230.4390.4450.3760.2590.309
    5.0800.4590.4580.4090.2450.301
    Table 1. Comparison of relative peak-values of leakage field at different testing points as source changes
    Linshen Xie, Wei Wu, Xiangqin Zhu. Regularity analysis of leakage-field from vertically polarized bounded wave electromagnetic pulse simulator with distributed load[J]. High Power Laser and Particle Beams, 2020, 32(5): 055002