    Jing LI, Zhonghui SUN, Jinping NI, Hui TIAN. Method of Calibrating Target Distance Using Dual Zone-block Light Screen Velocity Measuring Device[J]. Acta Photonica Sinica, 2024, 53(2): 0212004 Copy Citation Text show less
    Schematic of velocity measurement by single zone-block device
    Fig. 1. Schematic of velocity measurement by single zone-block device
    Schematic of calibration by single zone-block device
    Fig. 2. Schematic of calibration by single zone-block device
    Schematic of velocity measurement by dual zone-block device
    Fig. 3. Schematic of velocity measurement by dual zone-block device
    Schematic of calibration by dual zone-block device
    Fig. 4. Schematic of calibration by dual zone-block device
    Curve of ΔSGH as a function of d
    Fig. 5. Curve of ΔSGH as a function of d
    Curve of ΔSGH as a function of L
    Fig. 6. Curve of ΔSGH as a function of L
    Schematic of test layout
    Fig. 7. Schematic of test layout
    Test site of calibration with dual zone-block device
    Fig. 8. Test site of calibration with dual zone-block device
    Firing sequencev23/(m·s-1tGH/μstHK/μsSGH1/mmSHK1/mm
    Average value74.8874.87
    1117.13638.6638.674.8074.80
    2154.60485.6483.675.0774.76
    3164.91454.0454.074.8774.87
    4169.84440.8441.674.8675.00
    5166.29449.8450.674.8074.93
    Table 1. Results of calibration by single zone-block device
    Firing sequencev23/(m·s-1vGK1/(m·s-1ΔvGK1/(m·s-1δvGK1/(‰)
    Average value0.221.55
    1117.13117.020.110.95
    2154.60154.240.362.31
    3164.91164.690.221.31
    4169.84169.580.251.50
    5166.29166.010.281.69
    Table 2. Results of velocity measurement used single zone-block calibration method
    Firing sequencet12/μst34/μst1G/μst1H/μstGH'/μstHK'/μs
    1862 2881 6153 23158 52528.6528.6
    2127 79130 44227 05234 88782.4782.6
    3883 9903 5157 06162 49541.6541.8
    4100 14102 28177 95184 09613.4613.6
    5808 9826 9143 76148 71495.8496.0
    Table 3. Times value sequence of projectile pass through screen
    Firing sequenceSGH2/mmSHK2/mmΔS1/mmΔS2/mm
    Average value74.9874.980.060.06
    175.0074.960.060.06
    274.9775.010.050.05
    374.9774.960.060.06
    474.9874.970.060.06
    574.9974.990.060.06
    Table 4. Results of calibration by dual zone-block device
    Firing sequencev23/(m·s-1vGK2/(m·s-1ΔvGK2/(m·s-1δvGK2/(‰)
    Average value0.050.37
    1117.13117.210.080.66
    2154.60154.490.110.70
    3164.91164.960.050.30
    4169.84169.860.020.12
    5166.29166.280.010.07
    Table 5. Results of velocity measurement used dual zone-block calibration method
    Jing LI, Zhonghui SUN, Jinping NI, Hui TIAN. Method of Calibrating Target Distance Using Dual Zone-block Light Screen Velocity Measuring Device[J]. Acta Photonica Sinica, 2024, 53(2): 0212004