• Optics and Precision Engineering
  • Vol. 22, Issue 1, 44 (2014)
HUANG Qiang1,*, WANG Min1, LI Ang1, HAN Xi-da2, and HE Yong-hong1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/ope.20142201.0044 Cite this Article
    HUANG Qiang, WANG Min, LI Ang, HAN Xi-da, HE Yong-hong. Symmetrical long range surface plasmon resonance sensing system[J]. Optics and Precision Engineering, 2014, 22(1): 44 Copy Citation Text show less
    References

    [1] QI P, LI Y, FENG M CH, et al.. Scanning surface plasmon resonance biosensor for array sample detection[J]. Opt. Precision Eng., 2012, 20(11): 2365-2372.(in Chinese)

    [2] HOMOLA J.Surface plasmon resonance sensors for detection of chemical and biological species [J].Chemical Reviews,2008,108(2): 462.

    [3] GORDON I J G, ERNST S. Surface plasmons as a probe of the electrochemical interface[J]. Surface Science, 1980, 101(1): 499-506.

    [4] NYLANDER C, LIEDBERG B, LIND T. Gas detection by means of surface plasmon resonance[J]. Sensors and Actuators, 1983, 3: 79-88.

    [5] SARID D.Long-range surface-plasma waves on very thin metal films [J].Physical Review Letters,1981,47(26): 1927-1930.

    [6] RAETHER H,KRETSCHMANN E.Radiative decay of non radiative surface plasmons excited by light [J].Z.Naturforsch.,1968,23: 2135-2136.

    [7] BAKER L R. Electromagnetic surface modes[J]. Journal of Modern Optics, 1983, 30(3): 257-257.

    [8] RAETHER H. Surface Plasmons on Smooth and Rough Surfaces and on Gratings[M]. Springer Tracts in Modern Physics, 1988: 111.

    [9] HOMOLA J. On the sensitivity of surface plasmon resonance sensors with spectral interrogation[J]. Sensors and Actuators B: Chemical, 1997, 41(1): 207-211.

    [10] HAO P, WU Y H. Data process of spectroscopic surface plasmon resonance analyzer based on noise analysis[J]. Opt. Precision Eng., 2009,17(9): 2159-2164.(in Chinese)

    [11] MAIER J S. Possible correlation between blood glucose concentration and the reduced scattering coefficient of tissues in the near infrared [J]. Optics Letters, 1994, 19(24): 2062-2064.

    [12] LIU Z Y, YANG L, LIU L, et al.. Parallel-scan based microarray imager capable of simultaneous surface plasmon resonance and hyperspectral fluorescence imaging [J]. Biosensors & Bioelectronics, 2011, 30: 180-187.

    [13] LIU L, HE Y H, ZHANG Y, et al.. Parallel scan spectral surface plasmon resonance imaging[J]. Applied Optics, 2008, 47(30): 5616-5621.

    CLP Journals

    [1] HE Hao, ZHANG Tao, YAO Jia, LI Chuan-yu, ZHOU Lian-qun, WANG Yi, LI Ming-yu, LI Hai-wen, DONG Wen-fei. Surface plasmon resonance sensor coated with poriferous MIPs for microcystin-LR detection[J]. Optics and Precision Engineering, 2015, 23(3): 723

    [2] LIU Yuan-yuan, XIONG Guang, WANG Yang, ZHU Lu. Design of multi resonant U shaped slots nano-antenna and their absorption properties[J]. Optics and Precision Engineering, 2017, 25(8): 2155

    HUANG Qiang, WANG Min, LI Ang, HAN Xi-da, HE Yong-hong. Symmetrical long range surface plasmon resonance sensing system[J]. Optics and Precision Engineering, 2014, 22(1): 44
    Download Citation