• Chinese Journal of Lasers
  • Vol. 51, Issue 2, 0204003 (2024)
Gan Huang, Shuangyun Shao*, and Jueting Luo
Author Affiliations
  • School of Physical Science and Engineering, Beijing Jiaotong University, Beijing 100044, China
  • show less
    DOI: 10.3788/CJL230812 Cite this Article Set citation alerts
    Gan Huang, Shuangyun Shao, Jueting Luo. Line-Scan Camera Calibration Method Based on Absolute Phase Target[J]. Chinese Journal of Lasers, 2024, 51(2): 0204003 Copy Citation Text show less
    References

    [1] Lu X D, Xue J P, Zhang Q C. High camera calibration method based on true coordinate computation of circle center[J]. Chinese Journal of Lasers, 47, 0304008(2020).

    [2] Liu Y K, Su X Y. New camera calibration technique based on phase measurement[J]. Opto-Electronic Engineering, 34, 65-69(2007).

    [3] Schmalz C, Forster F, Angelopoulou E. Camera calibration: active versus passive targets[J]. Optical Engineering, 50, 113601(2011).

    [4] Bell T, Xu J, Zhang S. Method for out-of-focus camera calibration[J]. Applied Optics, 55, 2346-2352(2016).

    [5] Mao X F, Su X Y, Liu Y K et al. Analysis on optical coordinate measurement based on phase target[J]. Acta Optica Sinica, 29, 2452-2457(2009).

    [6] Draréni J, Roy S, Sturm P. Plane-based calibration for linear cameras[J]. International Journal of Computer Vision, 91, 146-156(2011).

    [7] Hui B W, Wen G J, Zhang P et al. A novel line scan camera calibration technique with an auxiliary frame camera[J]. IEEE Transactions on Instrumentation and Measurement, 62, 2567-2575(2013).

    [8] Horaud R, Mohr R, Lorecki B. On single-scanline camera calibration[J]. IEEE Transactions on Robotics and Automation, 9, 71-75(1993).

    [9] Song K C, Hou B, Niu M H et al. Flexible line-scan camera calibration method using a coded eight trigrams pattern[J]. Optics and Lasers in Engineering, 110, 296-307(2018).

    [10] Li C, Li H Y, Zhang X et al. Coding line structured light based on a line-scan camera and its calibration[J]. Optics Express, 28, 24799-24812(2020).

    [11] Usamentiaga R. Static calibration for line-scan cameras based on a novel calibration target[J]. IEEE Transactions on Instrumentation and Measurement, 71, 5015812(2022).

    [12] Yuan S P, Bi D X, Li Z X et al. A static and fast calibration method for line scan camera based on cross-ratio invariance[J]. Journal of Modern Optics, 69, 619-627(2022).

    [13] Luna C A, Mazo M, Lazaro J L et al. Calibration of line-scan cameras[J]. IEEE Transactions on Instrumentation and Measurement, 59, 2185-2190(2010).

    [14] Li D D, Wen G J, Qiu S H. Cross-ratio-based line scan camera calibration using a planar pattern[J]. Optical Engineering, 55, 014104(2016).

    [15] An S Y, Zhu J P, Yang H Y et al. Simulation and experiment research on camera calibration based on absolute phase target[J]. Laser & Optoelectronics Progress, 59, 0412001(2022).

    [16] Su X Y, Zhang Q C, Chen W J. Three-dimensional imaging based on structured illumination[J]. Chinese Journal of Lasers, 41, 0209001(2014).

    [17] Zhang Q C, Wu Z J. Three-dimensional imaging technique based on Gray-coded structured illumination[J]. Infrared and Laser Engineering, 49, 0303004(2020).

    [18] Wang H R, Wu Z J, Zhang Q C et al. High-speed three-dimensional topography measurement method based on time multiplexing coding[J]. Acta Optica Sinica, 43, 0112003(2023).

    [19] Zhang Z Y. A flexible new technique for camera calibration[J]. IEEE Transactions on Pattern Analysis and Machine Intelligence, 22, 1330-1334(2000).

    [20] Lepetit V, Moreno-Noguer F, Fua P. EPnP: an accurate O(n) solution to the PnP problem[J]. International Journal of Computer Vision, 81, 155-166(2009).

    [21] Usamentiaga R, Garcia D F, de la Calle F J. Line-scan camera calibration: a robust linear approach[J]. Applied Optics, 59, 9443-9453(2020).

    Gan Huang, Shuangyun Shao, Jueting Luo. Line-Scan Camera Calibration Method Based on Absolute Phase Target[J]. Chinese Journal of Lasers, 2024, 51(2): 0204003
    Download Citation