• Acta Photonica Sinica
  • Vol. 50, Issue 9, 0911003 (2021)
Zongpeng WANG1, Chongzhou LAN1, Minru WEN2, and Chao YE1
Author Affiliations
  • 1Shenzhen Angell Technology Co., Ltd., Shenzhen, Guangdong58000, China
  • 2School of Physics & Optoelectronic Engineering, Guangdong University of Technology, Guangzhou510006, China
  • show less
    DOI: 10.3788/gzxb20215009.0911003 Cite this Article
    Zongpeng WANG, Chongzhou LAN, Minru WEN, Chao YE. X-ray Multi-energy Imaging Method Using Multi-layer Flat Panel Detector[J]. Acta Photonica Sinica, 2021, 50(9): 0911003 Copy Citation Text show less
    References

    [1] J BUSHBERG, J SEIBERT, E LEIDHOLDT et al. The essential physics of medical imaging, 3rd edition. Lippincott Williams & Wilkins(2012).

    [2] Qingyong ZHOU, Ziqing WEI, Kun JIANG等. Research on the test and calibration method of a focusing X-ray detector for pulsar navigation. Acta Photonica Sinica, 49(2020).

    [3] Jun SHI, Miao LI, Lindongying LUO等. An X-ray detection technology with multi-curvature bent crystal. Acta Photonica Sinica, 49(2020).

    [4] W BOWMAN, J ROBAR, M SATTARIVAND. Optimizing dual-energy X-ray parameters for the ExacTrac clinical stereoscopic imaging system to enhance soft-tissue imaging. Medical Physics, 44, 823-831(2017).

    [5] M KARCAALTINCABA, A AVKUT. Dual-energy CT revisited with multi-detector CT: review of principles and clinical applications. Diagnostic & Interventional Radiology, 17, 181-194(2011).

    [6] C MCCOLLOUGH, S LENG, L YU et al. Dual- and multi-energy CT: principles, technical approaches, and clinical applications. Radiology, 276, 637-653(2015).

    [7] R COLBETH, M ALLEN, D DAY et al. Flat-panel imaging system for fluoroscopy applications, 3336, 376-387(1998).

    [8] Zhenggan ZHOU, Shenghua TENG, Wei JIANG等. X-ray flat-panel-detector-based digital radiography and its image calibration. Journal of Beijing University of Aeronautics and Astronautics, 30, 689-701(2004).

    [9] J PUNNOOSE, J XU, A SISNIEGA et al. Technical Note: spektr 3.0—A computational tool for X-ray spectrum modeling and analysis. Medical Physics, 43, 4711-4717(2016).

    [10] J HSIEH, R MOLTHEN, C DAWSON et al. An iterative approach to the beam hardening correction in cone beam CT. Medical Physics, 27, 23-29(2000).

    [11] J HSIEH. Computed tomography-principles, design, artifacts and recent advances. Society of Photo-Optical Instrumentation Engineers Press(2009).

    [12] J ZHAO, B HIBBSOPSAHL, M HOPPLE. Dual energy X-ray imaging system and method for radiography and mammography. US Patent.

    [13] N ALLEC, S ABBASZADEH, K KARIM. Single-layer and dual-layer contrast-enhanced mammography using amorphous selenium flat panel detectors. Physics in Medicine & Biology, 56, 5903(2011).

    [14] W ZHAO, D VERNEKOHL, H FEI et al. A unified material decomposition framework for quantitative dual‐ and triple‐energy CT imaging. Medical Physics, 45, 2964-2977(2018).

    [15] S MAURINO, A BADANO, I A CUNNINGHAM et al. Theoretical and Monte Carlo optimization of a stacked three-layer flat-panel X-ray imager for applications in multi-spectral diagnostic medical imaging, 9783, 1-14(2016).

    Zongpeng WANG, Chongzhou LAN, Minru WEN, Chao YE. X-ray Multi-energy Imaging Method Using Multi-layer Flat Panel Detector[J]. Acta Photonica Sinica, 2021, 50(9): 0911003
    Download Citation