• Acta Photonica Sinica
  • Vol. 49, Issue 9, 0912003 (2020)
Ping SUN, Chao FAN, Qing DAI, Yu-xin TANG, Zhi-fang LEI, and Chun-hua HU
Author Affiliations
  • School of Physics and Electronics, Shandong Normal University, Jinan 250014, China
  • show less
    DOI: 10.3788/gzxb20204909.0912003 Cite this Article
    Ping SUN, Chao FAN, Qing DAI, Yu-xin TANG, Zhi-fang LEI, Chun-hua HU. A L-K Local Optical-flow-based Coordinate Profilometry by Using the Capture Line in Space[J]. Acta Photonica Sinica, 2020, 49(9): 0912003 Copy Citation Text show less
    A typical optical setup for 3-D surface measurement using fringe-projection
    Fig. 1. A typical optical setup for 3-D surface measurement using fringe-projection
    The measured height distribution of the spherical crown
    Fig. 2. The measured height distribution of the spherical crown
    The fringe pattern in experiment captured
    Fig. 3. The fringe pattern in experiment captured
    The calculated height distribution of the spherical crown
    Fig. 4. The calculated height distribution of the spherical crown
    The comparison of the cross section data between the calculated and its true value at y=0 mm in x direction
    Fig. 5. The comparison of the cross section data between the calculated and its true value at y=0 mm in x direction
    The comparison of the absolute error distribution of the measured crown height when the projector coordinates xP and zP are set as -25 mm and 0 mm respectively, the imaging distance z0 is 1 805 mm with that of 1 800 mm
    Fig. 6. The comparison of the absolute error distribution of the measured crown height when the projector coordinates xP and zP are set as -25 mm and 0 mm respectively, the imaging distance z0 is 1 805 mm with that of 1 800 mm
    The comparison of the absolute error distribution of the measured crown height when z0 and zP are set as -1 800 mm and 0 mm respectively, xP is -30 mm with that of -25 mm
    Fig. 7. The comparison of the absolute error distribution of the measured crown height when z0 and zP are set as -1 800 mm and 0 mm respectively, xP is -30 mm with that of -25 mm
    The comparison of the absolute error distribution of the measured crown height when z0 and xP are set as 1 800 mm and -25 mm respectively, zP is 5 mm with that of 0mm
    Fig. 8. The comparison of the absolute error distribution of the measured crown height when z0 and xP are set as 1 800 mm and -25 mm respectively, zP is 5 mm with that of 0mm
    The fringe patterns in experiment captured
    Fig. 9. The fringe patterns in experiment captured
    The calculated height distribution of the mask surface
    Fig. 10. The calculated height distribution of the mask surface
    Ping SUN, Chao FAN, Qing DAI, Yu-xin TANG, Zhi-fang LEI, Chun-hua HU. A L-K Local Optical-flow-based Coordinate Profilometry by Using the Capture Line in Space[J]. Acta Photonica Sinica, 2020, 49(9): 0912003
    Download Citation