• Journal of Radiation Research and Radiation Processing
  • Vol. 41, Issue 5, 050701 (2023)
Xuejian WANG1, Guobing YU2, Jianyou GUO1,*, Feng XU3,**..., Xianbao GU2 and Yang PANG3,4|Show fewer author(s)
Author Affiliations
  • 1School of Physics and Optoelectronic Engineering, Anhui University, Hefei 230601, China
  • 2Radiation Environment Supervision Station, Anhui Provincial Department of Ecology and Environment, Hefei 230071, China
  • 3School of Nuclear Science and Technology, Harbin Engineering University, Harbin 150001, China
  • 4Institute of Atomic Energy, Heilongjiang Province, Harbin 150081, China
  • show less
    DOI: 10.11889/j.1000-3436.2023-0026 Cite this Article
    Xuejian WANG, Guobing YU, Jianyou GUO, Feng XU, Xianbao GU, Yang PANG. Study on the method of air absorbed dose rate measurement by NaI(Tl) detector[J]. Journal of Radiation Research and Radiation Processing, 2023, 41(5): 050701 Copy Citation Text show less
    References

    [1] M Andoh, H Yamamoto, T Kanno et al. Measurement of ambient dose equivalent rates by walk survey around Fukushima Dai-ichi Nuclear Power Plant using KURAMA-ⅡI until 2016. Journal of Environmental Radioactivity, 210, 105812(2019).

    [2] Nanping WANG, Shaoying PEI, Ying HUANG et al. Research on and application of methods for gamma-ray spectrometry in environmental monitoring. Radialization Protection, 25, 347-356(2005).

    [3] S Moriuchi. A new method of dose evaluation by spectrum-dose conversion operator and determination of the operator(1970).

    [4] H Terada, E J Sakai, M Katagiri. Environmental gamma-ray exposure rates measured by in-situ Ge(Li) spectrometer. Journal of Nuclear Science and Technology, 17, 281-290(1980).

    [5] H L Beck, J DeCampo, C Gogolak. In situ Ge(Li) and NaI(Tl) gamma-ray spectrometry(1972).

    [6] W M Lowder, H L Beck, W J Condon. Spectrometric determination of dose rates from natural and fall-out gamma-radiation in the United States, 1962-63. Nature, 202, 745-749(1964).

    [7] S Moriuchi, I Miyanaga. A spectrum etric method for measurement of low-evel gamma exposure dose. Health physics, 12, 541-551(1966).

    [8] H L Beck, W J Condon, W M Lowder. Spectrometric techniques for measuring environmental gamma radiation(1964).

    [9] Xiaona REN, Zunsu HU. Study on a weighted integration method by using NaI(Tl) detector for measuring dosimetric properties of the gamma-radiation field. Radialization Protection, 23, 65-73(2003).

    [10] W Chen, T C Feng, J Liu et al. A method based on Monte Carlo simulation for the determination of the G(E) function. Radiation Protection Dosimetry, 163, 217-221(2015).

    [11] Lili TANG. Study on the method and technology of measuring γ dose by γ energy spectrum full spectrum method(2010).

    [12] Huibin LI, Mingyan JIA, Rui WU et al. Calculation of spectrum to dose conversion function of portable HPGe γ spectrometer. Nuclear Electronics & Detection Technology, 33, 699-704(2013).

    [13] Wanchang LAI, Yanfang LIU, Lili TANG et al. Determination of air dose rate of γ-rays by using G(E) function method. Nuclear Techniques, 34, 679-682(2011).

    [14] Jun HE, Chaowen YANG. Measurement of γ absorption dose rate through measuring the full energy peak of γ spectrum. Nuclear Techniques, 37, 070403(2014).

    [15] Lei CAO, Yaofeng ZHANG, Yang YANG et al. Measurement of environmental level X, γ dose with conversion of complete spectra without deconvolution method of MC simulation. High Power Laser and Particle Beams, 34, 026005(2022).

    [16] S Moriuchi, T Nagaoka, K Saito et al. Theoretical analysis and dose evaluation of low-level external radiation in environment(1990).

    [17] Jianwei HUANG, Naiyan WANG. Efficiency calibration for a NaI scintillation detector based on Monte-Carlo process and preliminary measurements of bremsstrahlung. Acta Physica Sinica, 63, 180702(2014).

    [18] Yihua XIA. Advanced ionizing radiation protection course, 12-18(2010).

    Xuejian WANG, Guobing YU, Jianyou GUO, Feng XU, Xianbao GU, Yang PANG. Study on the method of air absorbed dose rate measurement by NaI(Tl) detector[J]. Journal of Radiation Research and Radiation Processing, 2023, 41(5): 050701
    Download Citation