• High Power Laser and Particle Beams
  • Vol. 32, Issue 2, 025018 (2020)
Chenggang Ma, Hongtao Li, Minghai Deng*, Ningxiang Cao, Tengfu Mo, Xiao Wang, and Zhiqiang Zhang
Author Affiliations
  • Key Laboratory of Pulsed Power, Institute of Fluid Physics, CAEP, Mianyang 621900, China
  • show less
    DOI: 10.11884/HPLPB202032.190378 Cite this Article
    Chenggang Ma, Hongtao Li, Minghai Deng, Ningxiang Cao, Tengfu Mo, Xiao Wang, Zhiqiang Zhang. Experimental research on reliability of 1 MV X-ray system for radiography[J]. High Power Laser and Particle Beams, 2020, 32(2): 025018 Copy Citation Text show less
    References

    [5] Smith J, Carlson R, Fulton R, et al. Cygnus dual beam radiography source[C]Proc of the 15th Pulsed Power Conference. 2005: 334337.

    [6] Smith J, Nelson D, mond E, et al. Cygnus perfmance in subcritical experiments[C]Proc of the 16th Pulsed Power Conference. 2007: 10891094.

    [9] Elsayed A. Reliability engineering[M]. Beijing: Electric Industry Press, 2013.

    CLP Journals

    [1] Hao Wei, Fengju Sun, Aici Qiu, Hailiang Yang, Jiahui Yin, Pengfei Zhang, Xiaofeng Jiang, Zhiguo Wang. Review of development of high energy pulsed X-ray accelerators for flash radiography[J]. High Power Laser and Particle Beams, 2022, 34(9): 094001

    Chenggang Ma, Hongtao Li, Minghai Deng, Ningxiang Cao, Tengfu Mo, Xiao Wang, Zhiqiang Zhang. Experimental research on reliability of 1 MV X-ray system for radiography[J]. High Power Laser and Particle Beams, 2020, 32(2): 025018
    Download Citation