• Acta Photonica Sinica
  • Vol. 48, Issue 3, 312001 (2019)
ZHANG Quan1、2、*, LI Xin1, LIU En-chao1, ZHANG Yan-na1, ZHAI Wen-chao1, and ZHENG Xiao-bing1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/gzxb20194803.0312001 Cite this Article
    ZHANG Quan, LI Xin, LIU En-chao, ZHANG Yan-na, ZHAI Wen-chao, ZHENG Xiao-bing. Opto-mechanical System Design and Field Experimental Analysis of Hyperspectral Ratio Radiometer[J]. Acta Photonica Sinica, 2019, 48(3): 312001 Copy Citation Text show less
    References

    [1] CZAPLA-MYERS J S, LEISSO N P, ANDERSON N J, et al. On-orbit radiometric calibration of Earth-observing sensors using the Radiometric Calibration Test Site (RadCaTS)[C]. SPIE, 2012, 8390: 83902B.

    [2] YIN Ya-peng, LI Xin, ZHENG Xiao-bing, et al. Design and implement of automated site observing radiometer[J]. Journal of Atmospheric and Environmental Optics, 2016, 11(1): 44-50.

    [3] SLATER P N, BIGGAR S F, HOLM R G, et al.Reflectance-and radiance-based methods for the in-flight absolute calibration of multispectral sensors[J]. Remote Sensing of Environment, 2015, 22(1): 11-37.

    [4] BIGGAR S F. In-flight methods for satellite sensor absolute radiometric calibration[D].Tucson: University of Arizona, 1990: 16-22.

    [5] GU Xing-fa, TIAN Guo-liang, YU Tao, et al. The radiometric calibration principle and method of space remote sensor[M]. Beijing: Science Press, 2013, 201-203.

    [6] WANG Min, ZHOU Shu-dao, HE Ming-yuan, et al. Characterizationand calibration method of satellite sensor radiometric calibration site[J]. Geomatics & Spatial Information Technology, 2015, 38(7): 24-27.

    [7] LI Xin, ZHENG Xiao-bing,YIN Ya-peng. Progress in automated site vicarious calibration technologies[J]. Journal of Atmospheric and Environmental Optics, 2014, 9(1): 17-21.

    [8] LI Xin, XUN Li-na, LIU En-chao, et al. Development of automated self-calibration spectra-radiometer[C]. SPIE, 2016, 10155: 101553W.

    [9] CZAPLA-MYERS J S, THOME K J, LESSO N P. Radiometric calibration of earth-observing sensors using an automated test site at Railroad Valley, Nevada[J]. Canadian Journal of Remote Sensing, 2010, 36(5): 474-487.

    [10] CZAPLA-MYERS J S. Automated ground-based methodology in support of vicarious calibration[D]. Tucson: The University of Arizona, 2006: 41-43, 54-57.

    [11] SCHMECHTIG C, SANTER R P, ROGER J C, et al. Automatic ground-based station for vicarious calibration[C]. SPIE,1997, 3221: 309-303.

    [12] KEROLA D X, BRUEGGE C J, GROSS H N, et al.. On-orbit calibration of the EO-1 Hyperion and advanced land imager(ALI) sensors using the LED spectrometer (LSpec) automated facility[J]. IEEE Transactions on Geoscience and Remote Sensing, 2009, 47(4): 1244-1255.

    [13] QIU Gang-gang, LI Xin, WEI Wei, et al. Experiment and analysis of on-orbit radiometric calibration for remote sensors based on in-site automated observation technology[J] . Acta Optica Sinica, 2016, 36(7): 0701001.

    [14] DAI Cai-hong, YU Jia-lin, YU Jing, et al. Calculation of the equivalent radiation plane for the spherical entrance optics[J].Acta Metrologrica Sinica, 2006, 27(3): 236-240.

    [15] SHI Shun-xiang, WANG Xue-en, LIU Jin-song. Physical optics and applied optics[M].Xi′an: Xidian University Press, 2008, 332-336.

    [16] JIN Wei-qi, HU Wei-jie. Radiometry, luminance and chromaticity[M]. Beijing: Beijing Institute of Technology Press, 2003,34.

    [17] LI Xin, ZHENG Xiao-bing, HONG Jin, et al. Optical and mechanical design of SWIR hyperspectral field spectroradiometer[J]. Optics and Precision Engineering, 2007, 15(11): 1656-1661.

    [18] LIU En-chao, LI Xin, WEI Wei, et al. Automatic field calibration and analysis of satellite based on hyper-spectral ratio radiometer[J]. Spectroscopy and Spectral Analysis, 2016, 36(12): 4076-4081.

    ZHANG Quan, LI Xin, LIU En-chao, ZHANG Yan-na, ZHAI Wen-chao, ZHENG Xiao-bing. Opto-mechanical System Design and Field Experimental Analysis of Hyperspectral Ratio Radiometer[J]. Acta Photonica Sinica, 2019, 48(3): 312001
    Download Citation