• Optics and Precision Engineering
  • Vol. 21, Issue 7, 1780 (2013)
LIU Zheng-kun*, LIU Ying, QIU Ke-qiang, XU Xiang-dong, and FU Shao-jun
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3788/ope.20132107.1780 Cite this Article
    LIU Zheng-kun, LIU Ying, QIU Ke-qiang, XU Xiang-dong, FU Shao-jun. Design and fabrication of soft X-ray double frequency grating[J]. Optics and Precision Engineering, 2013, 21(7): 1780 Copy Citation Text show less
    References

    [1] SMITH R F, DUNN J, NILSE J, et al.. Picosecond X-ray laser interferometry of dense plasmas [J]. Phys. Rev. Lett., 2002,89: 065004-1.

    [2] JORGE F, JORGE J R, MARIO C M, et al.. Picosecond-resolution soft-X-ray laser plasma interferometry [J]. Applied Optics, 2004, 43(19): 3938-3946.

    [3] WYANT J C. Double frequency grating lateral shear interferometer [J]. Appled Optics, 1973, 12(9): 2057-2060.

    [4] QIAN J Y, MING H, XIE J P. Application of double frequency grating shearing interferometry in measurement of coherece of laser Light [J]. Opt. Precision Eng., 1996, 4(5): 139-143. (in Chinese)

    [5] KEVIN L B. X-ray wavefront analysis and phase reconstruction with a two-dimensional shearing interferometer [J]. Optical Engineering, 2009, 48(8): 086501.

    [6] CHEN G H, CHEN L, LIU S X. Electron density measurement for C-Gun plasma using shearing interferometer [J]. Acta Photonica. Sin., 2007, 36(12): 2192-2195. (in Chinese)

    [7] LIU Y, TAN X, LIU ZH K, et al.. Soft X-ray holographic grating beam splitter including a double frequency grating for interferometer pre-alignment [J]. Optics Express, 2008, 16(19): 14761-14770.

    [8] TAN X, LIU Y, XU X D, et al.. 13.9 nm Laminar grating as beam splitter [J]. Opt. Precision Eng., 2009,17(1): 33-37. (in Chinese)

    [9] FU SH J, HONG Y L, TAO X M, et al.. Experimental research of double frequency grating with ion beam etching technique [J]. Chinese Journal of Quantum Electronics, 1992, 9(2): 186-190. (in Chinese)

    [10] SUN X Q, MING H, XIE J P, et al.. Measurement of the thermal lensing of a Ti: sapphire rod with double frequency holographic grating [J]. Chinese Journal of Lasers, 1995, 22(2): 126-128. (in Chinese)

    [11] LI L F. Electromagnetic theory of grating [M].2003: 13-14.(In Chinese)

    [12] ZHAO J S, LI L F, WU ZH H. In-situ self-monitoring of latent image in fabrication of holographic gratings [J]. Acta Optica Sinica, 2004,24(6): 851-858. (in Chinese)

    [13] XU X D, LIU ZH K, QIU K Q, et al.. Fabrication of 1 200 lp/mm laminar gratings for 1m Seya-Namioka monochromator at NSRL [J]. Opt. Precision Eng., 2012, 20(1): 1-8. (in Chinese)

    CLP Journals

    [1] SUI Guo-rong, ZHU Ze-wei, WANG Ying, JIA Xing-wei, SHAN Xin-zhi. Synchrotron radiation X-ray fluorescence spectrometer based on three crystals and multi-axis linkage[J]. Optics and Precision Engineering, 2017, 25(11): 2878

    LIU Zheng-kun, LIU Ying, QIU Ke-qiang, XU Xiang-dong, FU Shao-jun. Design and fabrication of soft X-ray double frequency grating[J]. Optics and Precision Engineering, 2013, 21(7): 1780
    Download Citation