• Acta Photonica Sinica
  • Vol. 46, Issue 3, 311004 (2017)
ZHANG Quan1、2、*, HUANG Shu-hua1, ZHAO Xin1, SI Fu-qi1, ZHOU Hai-jin1, WANG Yu1, and LIU Wen-qing1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/gzxb20174603.0311004 Cite this Article
    ZHANG Quan, HUANG Shu-hua, ZHAO Xin, SI Fu-qi, ZHOU Hai-jin, WANG Yu, LIU Wen-qing. The Design and Implementation of CCD Refrigeration System of Imaging Spectrometer[J]. Acta Photonica Sinica, 2017, 46(3): 311004 Copy Citation Text show less
    References

    [1] WANG Wei, SHEN Zhi-xue. Optical system design of LCTF-based airborne high spectral resolution camera[J]. Acta Photonica Sinica, 2015, 44(7): 0711003.

    [2] CHEN Wei, ZHENG Yu-quan, XUE Qing-sheng. Optical system design of airborne wide field-of-view hyperspectral imager[J]. Acta Photonica Sinica, 2014, 43(10): 1022001.

    [3] ZHAO Min-jie, SI Fu-qi, LU Yi-huai, et al. Spectral image correction method for space-born differential optical absorption spectrometer[J]. Acta Optica Sinica, 2015, 35(12): 1230002.

    [4] ZHOU Hai-jin, LIU Wen-qing, SI Fu-qi, et al. Spectral calibration for space-borne differential optical absorption spectrometer[J]. Spectroscopy and Spectral Analysis, 2012, 32(11): 2881-2885.

    [5] WU Xing-xing, LIU Jin-guo, ZHOU Huai-de, et al. Influence of cooling on imaging quality of EMCCD camera[J]. Optics and Precision Engineering, 2015, 23(10z): 528-532.

    [6] LIU Jin, SI Fu-qi, ZHOU Hai-Jin, et al. Observation of two-dimensional distributions of NO2 with airborne imaging DOAS technology[J]. Acta Physica Sinica, 2015, 64(3): 034217.

    [7] WANG Yu, LU Yi-huai, Zhao Xin, et al. Design and implementation of CCD imaging circuit for satellite-borne DOAS spectrometer[J]. Laser & Infrared, 2015, 45(6): 664-668.

    [9] ZHANG Yu-heng, WEI Ming-zhi, SONG Qian, et al. Development of an astronomical modularized CCD universal controller[J]. Acta Photonica Sinica, 2016, 45(11): 1112003.

    [10] GAO Zhi-fan, ZHANG Hong-ping, WU Qiong-shui, et al. Calibration and characterization of an AOTF-based hyperspectral imaging system[J]. Acta Photonica Sinica, 2015, 44(7): 0711001.

    [11] E2VCompany. CCD47-20Datasheet[EB/OL]. (2007-09) http: //www.e2 v.com/resources/account/download-datasheet/1427.

    [12] HUANG Jian-qiang, ZHAI Bing, HE Qi-xin, et al. A temperature control for near-infrared semiconductor laser used in gas detection[J]. Acta Photonica Sinica, 2014, 43(6): 614003.

    [13] LI Jiang-lan, SHI Yun-bo, ZHAO Peng-fei, et al. High precision thermostat system with TEC for laser diode[J]. Infrared and Laser Engineering, 2014, 43(6): 1746-1749.

    [14] LIU Yun-fang, ZHANG Xiao, LI Jian-wei, et al. Design of analog PID circuit system with parameter auto-tuning[J]. Cryoenics, 2013, 2: 69-72.

    [15] WANG Zhuo, MIN Kun-long, BAI Xue-bing, et al. Temperature control of semiconductor laser in gas sensor[J]. Transduser and Micsrosystem Technologies, 2013, 32(6): 43-46.

    CLP Journals

    [1]  BAIYunfei, YE Song, LI Zhiwei, SHI Hailiang, XIONG Wei, WANG Xinqiang, WANG Jiejun, ZHANG Wentao. Design of Temperature Control System for Mid-Infrared Detector Used in Gas Detection[J]. Journal of Atmospheric and Environmental Optics, 2019, 14(5): 351

    ZHANG Quan, HUANG Shu-hua, ZHAO Xin, SI Fu-qi, ZHOU Hai-jin, WANG Yu, LIU Wen-qing. The Design and Implementation of CCD Refrigeration System of Imaging Spectrometer[J]. Acta Photonica Sinica, 2017, 46(3): 311004
    Download Citation