• Chinese Journal of Lasers
  • Vol. 45, Issue 8, 804007 (2018)
Wang Jiannan, Li Wei, Liu Jietao, Sun Xueying, Guo Chengfei, and Shao Xiaopeng
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3788/CJL201845.0804007 Cite this Article Set citation alerts
    Wang Jiannan, Li Wei, Liu Jietao, Sun Xueying, Guo Chengfei, Shao Xiaopeng. Measuring Optical Transmission Matrix Based on Three Steps Phase Shift Interferometry and Focusing[J]. Chinese Journal of Lasers, 2018, 45(8): 804007 Copy Citation Text show less
    Comparison between modulation in Hadamard basis and Cartesian basis. (a) Cartesian basis, gray is not reflection pixel, equals to 0, white is reflection pixel, equals to 1; (b) Hadamard basis, gray and white are both reflection pixels, gray equals to -1 and white equals to 1, phase lag of gray is π comparing to white
    Fig. 1. Comparison between modulation in Hadamard basis and Cartesian basis. (a) Cartesian basis, gray is not reflection pixel, equals to 0, white is reflection pixel, equals to 1; (b) Hadamard basis, gray and white are both reflection pixels, gray equals to -1 and white equals to 1, phase lag of gray is π comparing to white
    Schematic of focusing through scattering medium based on OTM
    Fig. 2. Schematic of focusing through scattering medium based on OTM
    OTM measuring system of scattering medium. (a) Optical schematic of measuring matrix and focusing; (b) experimental devices of measuring matrix and focusing
    Fig. 3. OTM measuring system of scattering medium. (a) Optical schematic of measuring matrix and focusing; (b) experimental devices of measuring matrix and focusing
    Histogram distributions and fitting results of real part and imaginary part of OTM of frosted glass at Hadamard basis and Cartesian basis. (a) Imaginary part of KH and KD; (b) real part of KH and KD
    Fig. 4. Histogram distributions and fitting results of real part and imaginary part of OTM of frosted glass at Hadamard basis and Cartesian basis. (a) Imaginary part of KH and KD; (b) real part of KH and KD
    Single point focusing. (a) Single point focusing goal; (b) speckle detected by camera; (c) focusing result of single point
    Fig. 5. Single point focusing. (a) Single point focusing goal; (b) speckle detected by camera; (c) focusing result of single point
    Multipoint focusing. (a) Two points focusing goal; (b) speckle detected by camera with two points focusing; (c) focusing result of two points; (d) three points focusing goal; (e) speckle detected by camera with three points focusing; (f) focusing result of three points
    Fig. 6. Multipoint focusing. (a) Two points focusing goal; (b) speckle detected by camera with two points focusing; (c) focusing result of two points; (d) three points focusing goal; (e) speckle detected by camera with three points focusing; (f) focusing result of three points
    Enhancement factors of single point focusing under different conditions based on OTM. (a) Different focusing positions; (b) different camera positions
    Fig. 7. Enhancement factors of single point focusing under different conditions based on OTM. (a) Different focusing positions; (b) different camera positions
    Measuring depth of focus based on OTM
    Fig. 8. Measuring depth of focus based on OTM
    Wang Jiannan, Li Wei, Liu Jietao, Sun Xueying, Guo Chengfei, Shao Xiaopeng. Measuring Optical Transmission Matrix Based on Three Steps Phase Shift Interferometry and Focusing[J]. Chinese Journal of Lasers, 2018, 45(8): 804007
    Download Citation