• Acta Photonica Sinica
  • Vol. 42, Issue 3, 315 (2013)
LIU Bo*, ZHU Yong, CHEN Jian-jun, WEI Wei, ZHANG Jie, and WANG Ning
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3788/gzxb20134203.0315 Cite this Article
    LIU Bo, ZHU Yong, CHEN Jian-jun, WEI Wei, ZHANG Jie, WANG Ning. Analysis of Tolerance of Tilting Mirror and Experiment in Novel Fourier Transform Spectrometer[J]. Acta Photonica Sinica, 2013, 42(3): 315 Copy Citation Text show less
    References

    [1] KONG Yan-mei, LIANG Jing-qiu, WANG Bo, et al. The investigation and simulation of a novel spatially modulated micro-fourier transform spectrometer[J]. Spectroscopy and Spectral Analysis, 2009, 29(4): 1142-1146.

    [2] MANZARDO O, HERZIG H P, MARXER C R, et al. Miniature time-scanning Fourier transform spectrometer based on silicon technology[J]. Optics Letters, 1999, 24(23): 1705-1707.

    [3] SIN J, LEE W H, POPA D, et al. Assembled Fourier transform micro-spectrometer[J]. Micromachining and Micro Fabrication Process Technology Xi, 2006, 6109(04): 1-8.

    [4] DUDLEY D, DUNCAN W, SLAUGHTER J. Emerging digital micromirror device (DMD) applications[C]. SPIE, 2003, 4985: 14-25.

    [5] KRAFT M, KENDA A, FRANK A, et al. Single detector micro-electro-mechanical scanning grating spectrometer[J]. Analytical and Bioanalytical Chemistry, 2006, 386(5): 1259-1266.

    [6] WEI Wei, HUANG Shang-lian, CHEN Wei-min, et al. A novel near-infrared spectra detection system based on MEMS grating light modulators[J]. Spectroscopy and Spectral Analysis, 2010, 30(3): 846-850.

    [7] MO Xiang-xia, WEN Zhi-yu, ZHANG Zhi-hai, et al. Design and experimental of digtal mcro-mirror spectrometer[J]. Acta Photonica Sinica, 2011, 40(9): 1356-1360.

    [8] CONG Feng, BO Wang, Zhangzhu Liang, et al.Miniaturization of step mirrors in a static Fourier transform spectrometer: theory and simulation[J]. Journal of Optics Society, 2011, 28(1): 128-133.

    [9] LACAN A, BREON F M, ROSAK A, et al. A static Fourier spectrometer for atmospheric sounding: concept and experimental implementation[J]. Optics Express, 2010, 18(8): 8311-8331.

    [10] FU Jian-guo, LIANG Jing-qiu, LIANG Zhong-zhu. Analysis and design for the optical system of a static infrared Fourier transform spectrometer[J]. Acta Optica Sinica, 2012, 32(2): 266-273.

    [11] XIANG-LI Bin, YANG Jian-feng, GAO Zhan, et al. On the tolerance of the mirror tilting in Fourier transform interferometer[J]. Acta Photonica Sinica, 1997, 26(2): 132-135.

    [12] XIANG-LI Bin. On the key design issues in Fourier Transform spectrometers[J]. Acta Photonica Sinica, 1997, 26(6): 550-554.

    [13] ZENG Li-Bo, YIN Bang-sheng, HE Bing, et al. Error analysis of moving mirror in Fourier transform interferometer[J]. Optics and Precision Engineering, 2006, 14(2): 191-196.

    [14] YANG Qing-hua, ZHOU Ren-kui, ZHAO Bao-chang. Tilt tolerance of the moving mirror in Michelson interferometric spectrometer [J]. Acta Photonica Sinica, 2009, 38(3): 677-680.

    [15] YIN Bang-sheng, ZENG Li-bo, LEI Jun-feng, et al. Error ananlysis of the mirror tilting in spectrum transform interferometer and the study on dynamic alignment technology[J]. Optical Instruments, 2006, 28(1): 74-80.

    [16] LIU Zhi-chao, ZHANG Ji-long, WANG Zhi-bin, et al. Static Fourier transform spectrometer used in wide field of view detection[J]. Acta Photonica Sinica, 2009, 38(11): 2839-2843.

    [17] XIANG-LI Bin, YUAN Yan. Some aspects of the data processing of the single sided interferogram[J]. Acta Photonica Sinica, 2006, 35(12): 1869-1874.

    CLP Journals

    [1] YU Shu-hai, WANG Jian-li, DONG Lei, LIU Xin-yue, WANG Liang, LI Hong-zhuang, LIU Jie. Application Informal Phase Closure about Image Reconstruction Algorithm Based on Fourier Telescopy[J]. Acta Photonica Sinica, 2015, 44(5): 511002

    [2] SHI Lei, LIU Jia, GAO Wu, ZHANG Qian-xuan, WANG Wei. Design of a Moving Mirror Scanning System in Fourier Transform Infrared Spectrometer[J]. Acta Photonica Sinica, 2015, 44(4): 430002

    [3] ZHANG Yu, LUO Xiu-juan, XIA Ai-li, CAO Bei, CHENG Zhi-yuan, ZENG Zhi-hong, SI Qing-dan, WANG Bao-feng. Image Quality Evaluation and Analysis in Fourier Telescopy for Laboratory Demonstration[J]. Acta Photonica Sinica, 2014, 43(3): 311001

    LIU Bo, ZHU Yong, CHEN Jian-jun, WEI Wei, ZHANG Jie, WANG Ning. Analysis of Tolerance of Tilting Mirror and Experiment in Novel Fourier Transform Spectrometer[J]. Acta Photonica Sinica, 2013, 42(3): 315
    Download Citation