• Chinese Journal of Lasers
  • Vol. 19, Issue 11, 825 (1992)
[in Chinese] and [in Chinese]
Author Affiliations
  • [in Chinese]
  • show less
    DOI: Cite this Article Set citation alerts
    [in Chinese], [in Chinese]. Temperature measurement using laser induced thermally-assisted vibrational fluorescence of BaCl[J]. Chinese Journal of Lasers, 1992, 19(11): 825 Copy Citation Text show less

    Abstract

    A new method called laser induced thermally-assisted vibrational fluorescence (LITVF) for combustion temperature measurement was proposed. The collisional relaxation model of the populations in the excited electro-vibrational states were established. By using light at 517.0nm to excite the transition of C2II1/2(v= l)-X2(v= 0), the LITVF spectra of Bad were obtained in the seeded premised liquified petroleum gas/air flame, from which the temperature were calculated. The results indicate that the accuracy of this method is σT=30K when BaCl is used as the seeded molecule.
    [in Chinese], [in Chinese]. Temperature measurement using laser induced thermally-assisted vibrational fluorescence of BaCl[J]. Chinese Journal of Lasers, 1992, 19(11): 825