Journals
Advanced Photonics
Photonics Insights
Advanced Photonics Nexus
Photonics Research
Advanced Imaging
View All Journals
Chinese Optics Letters
High Power Laser Science and Engineering
Articles
Optics
Physics
Geography
View All Subjects
Conferences
CIOP
HPLSE
AP
View All Events
News
About CLP
Search by keywords or author
Login
Registration
Login in
Registration
Search
Search
Articles
Journals
News
Advanced Search
Top Searches
laser
the
2D Materials
Transformation optics
Quantum Photonics
Home
All Issues
Journals >
INFRARED
Contents
2022
Volume: 43 Issue 2
9 Article(s)
Select format
EndNote (RIS)
BibTex
Plain Text
Export citation format
[in Chinese]
.
showLess
INFRARED
Publication Date: Jan. 01, 1900
Vol. 43, Issue 2, 1 (2022)
Get PDF
Development of Long-Wavelength 1280×1024 HgCdTe Detectors with 10 μm Pitch
Jiao-jiao QI, Xiao-yu FENG, Yan-guan CHEN, Ti NING, Shi-guang LIU, Hao SUN, and Jian KANG
With the advancement of infrared technology, infrared detector assemblies are developing towards smaller size and higher resolution. Small pitch and large area array specifications are important directions for the development of long-wavelength detectors. Through the research of 10 m pitch, 9 m cut-off wavelength, and
With the advancement of infrared technology, infrared detector assemblies are developing towards smaller size and higher resolution. Small pitch and large area array specifications are important directions for the development of long-wavelength detectors. Through the research of 10 m pitch, 9 m cut-off wavelength, and 1280×1024 long-wave detector arrays, breakthroughs have been made in 10 m-pitch long-wavelength pixel junction technology, 10 m-pitch indium column preparation and interconnection technology. A long-wavelength 1280×1024 HgCdTe detector chip with an effective pixel rate of 994% or more and a non-uniformity of less than or equal to 4% has been developed..
showLess
INFRARED
Publication Date: Jan. 01, 1900
Vol. 43, Issue 2, 1 (2022)
Get PDF
Overview of Hardware-in-the-loop Infrared Multi-band Target Simulation Technologies Abroad
Yan-yun HAO, and Song-qing ZHAO
In order to evaluate the infrared multi-band imaging-guided weapon accurately, the infrared multi-band target simulation technology has become a research hotspot at home and abroad. In this paper, the development status of hardware-in-the-loop infrared multi-band target simulation system abroad in recent years is intro
In order to evaluate the infrared multi-band imaging-guided weapon accurately, the infrared multi-band target simulation technology has become a research hotspot at home and abroad. In this paper, the development status of hardware-in-the-loop infrared multi-band target simulation system abroad in recent years is introduced in detail from the aspects of the composition, working principle, technical indicators and characteristics,which has a certain reference significance for the subsequent development of the domestic infrared multi-band target simulation technology..
showLess
INFRARED
Publication Date: Jan. 01, 1900
Vol. 43, Issue 2, 7 (2022)
Get PDF
Research on Rapid Measurement Method of Indium Columns Height
Peng ZHANG, Xiao-yu FENG, and Yi ZHANG
In the process test of indium column evaporation of infrared detector, sometimes it is necessary to measure a large amount of indium column heights, so the measurement method of indium column height is studied in this paper. The manual method which measures point by point can get accurate results. But the measurement s
In the process test of indium column evaporation of infrared detector, sometimes it is necessary to measure a large amount of indium column heights, so the measurement method of indium column height is studied in this paper. The manual method which measures point by point can get accurate results. But the measurement speed is slow and it takes a lot of time.The rapid automatic measurement method uses the scanning function of the microscope and the image recognition technology to automatically identify the indium columns. It can obtain the heights of all indium columns at one time, so the measurement speed is very fast.The steps, procedures and key option settings of the two methods are introduced in detail in this paper.It is estimated that the second rapid measurement method only takes 30 minutes to measure the heights of 1000 indium columns, reducing the measurement time by 76% and greatly improving the measurement efficiency.Finally, the advantages and disadvantages of the two different measurement methods are analyzed..
showLess
INFRARED
Publication Date: Jan. 01, 1900
Vol. 43, Issue 2, 15 (2022)
Get PDF
Finite Element Analysis of Thermal Stress of 2048×2048 HgCdTe Infrared Focal Plane Dewar Cold Head
Xiong XIONG, Ming-deng HU, Jian-le WU, yu DUAN, Yong-qiang ZHOU, Yu DU, and Jian-hong MAO
The original structure and the added balance layer structure of the 2048×2048 (15 m) infrared focal plane dewar cold head are analyzed by finite element method. Adding a balance layer with a lower expansion coefficient under the ceramic substrate can relieve the deformation and thermal stress of the detector chip
The original structure and the added balance layer structure of the 2048×2048 (15 m) infrared focal plane dewar cold head are analyzed by finite element method. Adding a balance layer with a lower expansion coefficient under the ceramic substrate can relieve the deformation and thermal stress of the detector chip to a certain extent. By increasing the diameter of the upper surface of the AlN balance layer, the warpage range beyond the center of the chip is reduced, and the problem of excessive stress concentration is alleviated. When the diameter exceeds the diagonal length of the chip, the maximum thermal stress decreases sharply, and finally tends to be stable; the deformation of the chip decreases rapidly. When the diameter is 36 mm, it reaches a minimum of 686 m; then it increases slowly and tends to be stable. When the diameter of the AlN balance layer exceeds the diagonal length of the chip, the influence of the thickness of the AlN balance layer on the chip deformation begins to decrease. The deformation and thermal stress of the large area array focal plane detector chip can be effectively improved by adding an AlN balance layer. The reliability of the detector Dewar component can be further optimized by adjusting the structure of the AlN balance layer..
showLess
INFRARED
Publication Date: Jan. 01, 1900
Vol. 43, Issue 2, 22 (2022)
Get PDF
A Design Method of Cold Shield for Infrared Detectors
Ya TIAN, Zhi-kai FU, and Guan WANG
Aiming at the problems of large number of clapboards and difficult assembly process in the traditional design scheme of infrared detector cold shield, a simplified design method of infrared detector cold shield is proposed in this paper. This method reduces the number of cold shield partitions, the thermal mass of cold
Aiming at the problems of large number of clapboards and difficult assembly process in the traditional design scheme of infrared detector cold shield, a simplified design method of infrared detector cold shield is proposed in this paper. This method reduces the number of cold shield partitions, the thermal mass of cold head and the limitation of space on cold shield design.Because this method ignores the window seat of thermal radiation, two kinds of cold shield structures of a mid-wave infrared detector are designed by using the traditional scheme and the simplified scheme respectively, and the LightTools software is used to simulate the influence of window seat thermal radiation on infrared detector and the suppression efficiency of cold shield to field light in order to validate its feasibility. The simulation results show that when the ambient temperature of the detector is 344 K, the noise difference caused by the thermal radiation of the window seat on the infrared detector is not more than 03 mV.The difference is negligible compared with the signal intensity, and the suppression efficiency of the two cold shields is only 02% different, which verifies the feasibility of the design method..
showLess
INFRARED
Publication Date: Jan. 01, 1900
Vol. 43, Issue 2, 28 (2022)
Get PDF
Applications of the FIB-SEM Dual Beam System in the Development of Infrared Focal Plane Detector
Qian LI, Ting HUANG, Wei-lin SHE, Dan WANG, and Wei-rong XING
The focused ion beam scanning electron microscope system combines the advantages of scanning electron microscope and focused ion beam system.Based on the advantages of high resolution, in-situ processing and observation, its applications in defect anatomical analysis, pixel anatomical analysis, transmission electron mi
The focused ion beam scanning electron microscope system combines the advantages of scanning electron microscope and focused ion beam system.Based on the advantages of high resolution, in-situ processing and observation, its applications in defect anatomical analysis, pixel anatomical analysis, transmission electron microscope sample preparation and circuit repair are studied in this paper. The method of locating pixels with problems and the specific process of circuit repair are introduced in detail, and its important role in the development of infrared focal plane detectors is illustrated.The system is an indispensable characterization means in the development of high-performance infrared detectors..
showLess
INFRARED
Publication Date: Jan. 01, 1900
Vol. 43, Issue 2, 34 (2022)
Get PDF
Influence of Height Difference Between Wedge Solder Joints on the Strength of Lead Wire
Yu-hui YUAN
As a key technology in infrared detector packaging, the quality of lead bonding directly affects the performance and service life of infrared detector components.The height between solder joints is adjusted by bonding ceramic gaskets of different thicknesses between the ceramic substrate and the readout circuit. After
As a key technology in infrared detector packaging, the quality of lead bonding directly affects the performance and service life of infrared detector components.The height between solder joints is adjusted by bonding ceramic gaskets of different thicknesses between the ceramic substrate and the readout circuit. After bonding, DAGE-SERIES-4000-PXY tension tester is used to obtain the lead tension under different height differences.Experimental results show that the lead strength is the highest when there is no ceramic gasket bonded between the ceramic substrate and the readout circuit. As the thickness of ceramic gasket increases, the lead strength decreases..
showLess
INFRARED
Publication Date: Jan. 01, 1900
Vol. 43, Issue 2, 40 (2022)
Get PDF
Research on the Parameters of the Resonant Cavity of the Super-large Ring Laser Gyroscope
Qiu-ye QUAN, Wen-ge GUO, Fei WANG, Xue-dong XU, Li-song ZHANG, Yu-ping GAO, and Shou-gang ZHANG
Large laser gyro is an inertial sensor based on Sagnac effect.As the size increases, the fundamental mode operation and gain become important parameters. Aiming at lens matching, discharge current size and cavity length, the characteristic parameters of ABCD matrix and Gaussian beam are calculated, and the influence of
Large laser gyro is an inertial sensor based on Sagnac effect.As the size increases, the fundamental mode operation and gain become important parameters. Aiming at lens matching, discharge current size and cavity length, the characteristic parameters of ABCD matrix and Gaussian beam are calculated, and the influence of the waist spot position of the ring cavity and the discharge current on the diaphragm under different side lengths are verified in this paper.The results show that the quality of the light spot at the light threshold is the best. At this time the light spot is the flattest, and the ratio is close to 1. The symmetrical structure is conducive to efficient signal reading.This has certain reference significance for the cavity design of large laser gyro..
showLess
INFRARED
Publication Date: Jan. 01, 1900
Vol. 43, Issue 2, 44 (2022)
Get PDF
Email Alert
Submit a Paper