• Chinese Optics Letters
  • Vol. 11, Issue 6, 061201 (2013)
Su’an Xu, Luc Chassagne, Suat Topcu, Le Chen, Jian Sun, and Tianhong Yan
DOI: 10.3788/col201311.061201 Cite this Article Set citation alerts
Su’an Xu, Luc Chassagne, Suat Topcu, Le Chen, Jian Sun, Tianhong Yan. Polarimetric interferometer for measuring nonlinearity error of heterodyne interferometric displacement system[J]. Chinese Optics Letters, 2013, 11(6): 061201 Copy Citation Text show less

Abstract

This letter presents a polarimetric interferometer (PI) that can measure the ellipsometric parameter \theta with an accuracy of 0.01o leading to a potential accuracy of 17 pm. The PI is constructed and compared with a commercial heterodyne interferometer (HI). Given its low nonlinearity, the PI is used to measure the residual nonlinearity of a heterodyne interferometric displacement system. A rotating half-wave plate is used to compensate for a part of the nonlinearity error caused by the misalignment of the axis between input polarizing states and beamsplitter.
Su’an Xu, Luc Chassagne, Suat Topcu, Le Chen, Jian Sun, Tianhong Yan. Polarimetric interferometer for measuring nonlinearity error of heterodyne interferometric displacement system[J]. Chinese Optics Letters, 2013, 11(6): 061201
Download Citation