• High Power Laser and Particle Beams
  • Vol. 33, Issue 4, 046002 (2021)
Yikun Qian1、2, Peng Feng2, Yixin Liu1, Yadi Zhu1, Yuchen Huang1、2, Song Zhang1、2, Peng He2, Biao Wei2, and Benjiang Mao1、*
Author Affiliations
  • 1China Academy of Engineering Physics, Mianyang 621900, China
  • 2College of Optoelectronics Engineering, Chongqing University, Chongqing 400044, China
  • show less
    DOI: 10.11884/HPLPB202133.200280 Cite this Article
    Yikun Qian, Peng Feng, Yixin Liu, Yadi Zhu, Yuchen Huang, Song Zhang, Peng He, Biao Wei, Benjiang Mao. Personal dosimeter calibration based on minitype reference radiation[J]. High Power Laser and Particle Beams, 2021, 33(4): 046002 Copy Citation Text show less
    References

    [1] ISO 40371: 1996, X gamma reference radiation f calibrating dosemeters doserate meters f determining their response as a function of photon energy—Part 1: Radiation acteristics production methods[S].

    [2] ISO 40372: 1997, X gamma reference radiation f calibrating dosemeters doserate meters f determining their response as a function of photon energy—Part 2: Dosimetry f radiation protection over the energy ranges 8 keV to 1.3 MeV 4 MeV to 9 MeV[S].

    [3] ISO 40373: 1999, X gamma reference radiation f calibrating dosemeters doserate meters f determining their response as a function of photon energy—Part 3: Calibration of area personal dosemeters the measurement of their response as a function of energy angle of incidence[S].

    [4] ISO 40374: 2004, X gamma reference radiation f calibrating dosemeters doserate meters f determining their response as a function of photon energy—Part 4: Calibration of area personal dosemeters in low energy X reference radiation fields[S].

    [5] Leitner A, Witzani J, Boutillon M, et al. International comparisons of air kerma standards in 137Cs gamma radiation[J]. Metrologia, 34, 169(1997).

    [6] AllisyRoberts P J, Burns D T, Takata N, et al. Comparison of the stards f air kerma of the NMIJ the BIPM f 137Cs γ rays[R]. Rappt International Bureau of Weights Measures, 2004, 12: 18.

    [7] Allisy-Roberts P J, Kessler C, Burns D T, et al. Comparison of the standards for air kerma of the LNE-LNHB and the BIPM for 137Cs gamma radiation[J]. Metrologia, 46, P06011(2009).

    [8] Kessler C, Roger P, Allisy-Roberts P J, et al. Comparison of standards for air kerma of the KRISS and the BIPM for 137Cs gamma radiation[J]. Metrologia, 47, P06022(2010).

    [9] Kessler C, Allisy-Roberts P J, Burns D T, et al. Comparison of the standards for air kerma of the ITN (Portugal) and the BIPM for 137Cs γ-rays[J]. Metrologia, 47, P06007(2009).

    [10] Liu Yixin, Wei Biao, Zhuo Renhong, et al. Determination of the conventional true value of gamma-ray air kerma in a minitype reference radiation[J]. Applied Radiation and Isotopes, 118, 238-245(2016).

    [11] Liu Yixin, Wei Biao, Xu Yang, et al. Feasibility study on determining the conventional true value of gamma-ray air kerma in a minitype reference radiation[J]. Nuclear Science and Techniques, 28, 3-7(2017).

    [13] Li Wenjie, Liu Yixin, Wei Biao, et al. Monte Carlo simulation investigation on the minitype reference radiation employed for the calibration of gamma ray dose or dose rate meters[J]. Journal of Radiological Protection, 38, 407-421(2018).

    [14] IEC 61526: 2010, Radiation protection instrumentation—Measurement of personal dose equivalents Hp(10) Hp(0.07) f X, gamma, neutron beta radiations—Direct reading personal dose equivalent meters[S].

    Yikun Qian, Peng Feng, Yixin Liu, Yadi Zhu, Yuchen Huang, Song Zhang, Peng He, Biao Wei, Benjiang Mao. Personal dosimeter calibration based on minitype reference radiation[J]. High Power Laser and Particle Beams, 2021, 33(4): 046002
    Download Citation