• Spectroscopy and Spectral Analysis
  • Vol. 40, Issue 12, 3743 (2020)
Li-juan DAI1、1、*, Le-ming DING1、1, Wei-tao LI1、1, and Zhi-yu QIAN1、1
Author Affiliations
  • 1[in Chinese]
  • 11. Department of Mechanical Engineering, Nantong University, Nantong 226019, China
  • show less
    DOI: 10.3964/j.issn.1000-0593(2020)12-3743-05 Cite this Article
    Li-juan DAI, Le-ming DING, Wei-tao LI, Zhi-yu QIAN. Study on the Application of Scattering Spectrum With Small Source-Detector Separation in Pain Measurement[J]. Spectroscopy and Spectral Analysis, 2020, 40(12): 3743 Copy Citation Text show less
    System configurationE: Electrode; C: Computer; WM: Wireless module; S: Spectrometer; LS: Light source; TS: The section of the optical probe; ACC: Anterior cingulate cortex
    Fig. 1. System configuration
    E: Electrode; C: Computer; WM: Wireless module; S: Spectrometer; LS: Light source; TS: The section of the optical probe; ACC: Anterior cingulate cortex
    Comparisons of Δ[HbO] and Δ[Hb] obtained by two methods
    Fig. 2. Comparisons of Δ[HbO] and Δ[Hb] obtained by two methods
    Changes of hemodynamic parameters of ACC in 10 minutes before and 10 minutes after the injection(a): Δ[HbO]; (b): Δ[Hb]; (c): Δ[HbT]
    Fig. 3. Changes of hemodynamic parameters of ACC in 10 minutes before and 10 minutes after the injection
    (a): Δ[HbO]; (b): Δ[Hb]; (c): Δ[HbT]
    Changes of hemodynamic parameters of ACC in 10 minutes before and 60 minutes after the injection
    Fig. 4. Changes of hemodynamic parameters of ACC in 10 minutes before and 60 minutes after the injection
    Statistics of the difference of hemodynamic parameters every 5 minutes
    Fig. 5. Statistics of the difference of hemodynamic parameters every 5 minutes
    The power ratio of local field potential (13~30 Hz) before and after the injection
    Fig. 6. The power ratio of local field potential (13~30 Hz) before and after the injection
    Difference statistics of power spectrum data of β wave every 5 minutes
    Fig. 7. Difference statistics of power spectrum data of β wave every 5 minutes
    Li-juan DAI, Le-ming DING, Wei-tao LI, Zhi-yu QIAN. Study on the Application of Scattering Spectrum With Small Source-Detector Separation in Pain Measurement[J]. Spectroscopy and Spectral Analysis, 2020, 40(12): 3743
    Download Citation